FabDigitFabDigit

Aluminum 5005A-H34 vs 5005A-O

Aluminum · 5005A temper comparison

5005A-H34 and 5005A-O are two conditions of the same aluminum grade, 5005A: H34 (strain hardened and stabilized, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5005A-H34 is the stronger of the two: yield strength 138 MPa (20 ksi) against 45 MPa (6.53 ksi) for 5005A-O, about 3.1 times as much; tensile strength follows at 159 MPa (23.1 ksi) vs 125 MPa (18.1 ksi). In exchange, 5005A-O is the more ductile: elongation 25% versus 8% for 5005A-H34, and 5005A-H34 is harder (41 HB vs 28 HB). 5005A-O runs hotter in service (200°C vs 150°C continuous). On the shop floor, 5005A-H34 machines more easily (fair vs poor).

5005A-H34Choose it when strength drives the design, or when the part is machined in volume.

5005A-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5005A-H34 vs 5005A-O: properties

5005A-H345005A-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

159 MPa23.1 ksi
125 MPa18.1 ksi

Yield Strength (0.2% offset)

138 MPa20 ksi
45 MPa6.5 ksi

Elongation at Break

8%
25%

Shear Strength

97 MPa14.1 ksi
76 MPa11 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
55 MPa8 ksi

Hardness, Brinell

41 HB
28 HB

Hardness, Vickers

45 HV
31 HV

Same in both: Elastic (Young's) Modulus 69.5 GPa10.1 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 632°C1,170 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Thermal Conductivity 200 W/m·K116 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.7 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 52 % IACS · Electrical Resistivity 3.32×10⁻⁸ Ω·m1.31 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
30 / 100

Weldability

88 / 100
92 / 100

Formability (cold)

74 / 100
95 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 40% · Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5005A

5005A-H34 vs 5005A-O — frequently asked

Is 5005A-H34 stronger than 5005A-O?

Yes. 5005A-H34 has a typical yield strength of 138 MPa (20 ksi) against 45 MPa (6.53 ksi) for 5005A-O — about 3.1 times as much. Tensile strength is 159 MPa (23.1 ksi) vs 125 MPa (18.1 ksi).

Which condition does FabDigit quote by default, H34 or O?

H14 is the default 5005A condition in the FabDigit quote flow (neither H34 nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5005A-H34 or 5005A-O?

5005A-H34. Its machinability rates fair (40/100) against poor (30/100) for 5005A-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5005A-H34 and 5005A-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.