FabDigitFabDigit

Aluminum 5005A-H111 vs 5005A-H14

Aluminum · 5005A temper comparison

5005A-H111 and 5005A-H14 are two conditions of the same aluminum grade, 5005A: H111 (slightly strain hardened) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5005A-H14 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 50 MPa (7.25 ksi) for 5005A-H111, about 3.0 times as much; tensile strength follows at 160 MPa (23.2 ksi) vs 115 MPa (16.7 ksi). In exchange, 5005A-H111 is the more ductile: elongation 20% versus 6% for 5005A-H14, and 5005A-H14 is harder (41 HB vs 30 HB). 5005A-H111 runs hotter in service (190°C vs 150°C continuous).

5005A-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5005A-H14Choose it when strength drives the design.

5005A-H111 vs 5005A-H14: properties

5005A-H1115005A-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

115 MPa16.7 ksi
160 MPa23.2 ksi

Yield Strength (0.2% offset)

50 MPa7.3 ksi
150 MPa21.8 ksi

Elongation at Break

20%
6%

Shear Strength

78 MPa11.3 ksi
97 MPa14.1 ksi

Fatigue Strength (Endurance Limit)

56 MPa8.1 ksi
62 MPa9 ksi

Hardness, Brinell

30 HB
41 HB

Hardness, Vickers

33 HV
45 HV

Same in both: Elastic (Young's) Modulus 69.5 GPa10.1 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 632°C1,170 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

201 W/m·K116 BTU/hr·ft·°F
200 W/m·K116 BTU/hr·ft·°F

Max Service Temperature (continuous)

190°C374 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.7 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 52 % IACS · Electrical Resistivity 3.32×10⁻⁸ Ω·m1.31 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

31 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

31%
40%

Weldability

92 / 100
88 / 100

Formability (cold)

92 / 100
70 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5005A

5005A-H111 vs 5005A-H14 — frequently asked

Is 5005A-H14 stronger than 5005A-H111?

Yes. 5005A-H14 has a typical yield strength of 150 MPa (21.8 ksi) against 50 MPa (7.25 ksi) for 5005A-H111 — about 3.0 times as much. Tensile strength is 160 MPa (23.2 ksi) vs 115 MPa (16.7 ksi).

Which condition does FabDigit quote by default, H111 or H14?

H14 is the default 5005A condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5005A-H111 or 5005A-H14?

5005A-H14. Its machinability rates fair (40/100) against poor (31/100) for 5005A-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5005A-H111 and 5005A-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.