FabDigitFabDigit

Aluminum 4343-H14 vs 4343-H18

Aluminum · 4343 temper comparison

4343-H14 and 4343-H18 are two conditions of the same aluminum grade, 4343: H14 (strain hardened, half hard) versus H18 (strain hardened, full hard). The chemistry is identical, so every difference below comes from the condition. 4343-H18 is the stronger of the two: yield strength 200 MPa (29 ksi) against 165 MPa (23.9 ksi) for 4343-H14, about 21% more; tensile strength follows at 215 MPa (31.2 ksi) vs 185 MPa (26.8 ksi). In exchange, 4343-H14 is the more ductile: elongation 4% versus 2% for 4343-H18, and 4343-H18 is harder (58 HB vs 52 HB). 4343-H14 runs hotter in service (120°C vs 100°C continuous).

4343-H14Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4343-H18Choose it when strength drives the design.

4343-H14 vs 4343-H18: properties

4343-H144343-H18

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

185 MPa26.8 ksi
215 MPa31.2 ksi

Yield Strength (0.2% offset)

165 MPa23.9 ksi
200 MPa29 ksi

Elongation at Break

4%
2%

Shear Strength

110 MPa16 ksi
120 MPa17.4 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
65 MPa9.4 ksi

Hardness, Brinell

52 HB
58 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 577°C1,071 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

120°C248 °F
100°C212 °F

Same in both: Thermal Conductivity 178 W/m·K103 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.6 µm/m·K12 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 41 % IACS · Electrical Resistivity 4.2×10⁻⁸ Ω·m1.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
59 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.81 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

36 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

34%
38%

Weldability

50 / 100
48 / 100

Formability (cold)

40 / 100
22 / 100

Same in both: Castability 75 / 100 · Brazeability / Solderability 98 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale4343

4343-H14 vs 4343-H18 — frequently asked

Is 4343-H18 stronger than 4343-H14?

Yes. 4343-H18 has a typical yield strength of 200 MPa (29 ksi) against 165 MPa (23.9 ksi) for 4343-H14 — about 21% more. Tensile strength is 215 MPa (31.2 ksi) vs 185 MPa (26.8 ksi).

Which condition does FabDigit quote by default, H14 or H18?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose 4343-H14 over 4343-H18?

Pick 4343-H14 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 4343-H18 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4343-H14 and 4343-H18 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.