FabDigitFabDigit

Aluminum 4104-H14 vs 4104-H18

Aluminum · 4104 temper comparison

4104-H14 and 4104-H18 are two conditions of the same aluminum grade, 4104: H14 (strain hardened, half hard) versus H18 (strain hardened, full hard). The chemistry is identical, so every difference below comes from the condition. 4104-H18 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 170 MPa (24.7 ksi) for 4104-H14, about 29% more; tensile strength follows at 240 MPa (34.8 ksi) vs 200 MPa (29 ksi). In exchange, 4104-H14 is the more ductile: elongation 5% versus 2% for 4104-H18, and 4104-H18 is harder (72 HB vs 60 HB). 4104-H14 runs hotter in service (120°C vs 100°C continuous).

4104-H14Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4104-H18Choose it when strength drives the design.

4104-H14 vs 4104-H18: properties

4104-H144104-H18

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

200 MPa29 ksi
240 MPa34.8 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
220 MPa31.9 ksi

Elongation at Break

5%
2%

Shear Strength

120 MPa17.4 ksi
135 MPa19.6 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
75 MPa10.9 ksi

Hardness, Brinell

60 HB
72 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 559°C1,038 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

157 W/m·K90.7 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
100°C212 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 450 J/g193 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 39 % IACS · Electrical Resistivity 4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
44 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.82 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

33%
38%

Weldability

33 / 100
30 / 100

Formability (cold)

40 / 100
20 / 100

Same in both: Castability 80 / 100 · Brazeability / Solderability 97 / 100 · Polishability 30 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale4104

4104-H14 vs 4104-H18 — frequently asked

Is 4104-H18 stronger than 4104-H14?

Yes. 4104-H18 has a typical yield strength of 220 MPa (31.9 ksi) against 170 MPa (24.7 ksi) for 4104-H14 — about 29% more. Tensile strength is 240 MPa (34.8 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, H14 or H18?

O is the default 4104 condition in the FabDigit quote flow (neither H14 nor H18). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4104-H14 or 4104-H18?

4104-H18. Its machinability rates fair (38/100) against poor (33/100) for 4104-H14.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4104-H14 and 4104-H18 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.