4104-F and 4104-H14 are two conditions of the same aluminum grade, 4104: F (as fabricated) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 4104-H14 is the stronger of the two: yield strength 170 MPa (24.7 ksi) against 80 MPa (11.6 ksi) for 4104-F, about 113% more; tensile strength follows at 200 MPa (29 ksi) vs 150 MPa (21.8 ksi). In exchange, 4104-F is the more ductile: elongation 6% versus 5% for 4104-H14, and 4104-H14 is harder (60 HB vs 50 HB). 4104-F runs hotter in service (150°C vs 120°C continuous).

4104-FChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4104-H14Choose it when strength drives the design.

4104-F vs 4104-H14: properties

4104-F4104-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

150 MPa21.8 ksi
200 MPa29 ksi

Yield Strength (0.2% offset)

80 MPa11.6 ksi
170 MPa24.7 ksi

Elongation at Break

6%
5%

Shear Strength

100 MPa14.5 ksi
120 MPa17.4 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
65 MPa9.4 ksi

Hardness, Brinell

50 HB
60 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 559°C1,038 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
157 W/m·K90.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 450 J/g193 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
39 % IACS

Electrical Resistivity

4.3×10⁻⁸ Ω·m1.69 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.82 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
33%

Weldability

35 / 100
33 / 100

Formability (cold)

50 / 100
40 / 100

Same in both: Castability 80 / 100 · Brazeability / Solderability 97 / 100 · Polishability 30 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale4104

4104-F vs 4104-H14 — frequently asked

Is 4104-H14 stronger than 4104-F?

Yes. 4104-H14 has a typical yield strength of 170 MPa (24.7 ksi) against 80 MPa (11.6 ksi) for 4104-F — about 113% more. Tensile strength is 200 MPa (29 ksi) vs 150 MPa (21.8 ksi).

Which condition does FabDigit quote by default, F or H14?

O is the default 4104 condition in the FabDigit quote flow (neither F nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 4104-F over 4104-H14?

Pick 4104-F when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 4104-H14 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4104-F and 4104-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.