FabDigitFabDigit

Aluminum 4043-AW vs 4043-F

Aluminum · 4043 temper comparison

4043-AW and 4043-F are two conditions of the same aluminum grade, 4043: AW (as-welded deposit) versus F (as fabricated). The chemistry is identical, so every difference below comes from the condition. 4043-F is the stronger of the two: yield strength 120 MPa (17.4 ksi) against 55 MPa (7.98 ksi) for 4043-AW, about 118% more; tensile strength follows at 180 MPa (26.1 ksi) vs 165 MPa (23.9 ksi). 4043-F is the more ductile: elongation 12% versus 8% for 4043-AW, and 4043-F is harder (50 HB vs 45 HB).

4043-FChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

4043-AW vs 4043-F: properties

4043-AW4043-F

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

165 MPa23.9 ksi
180 MPa26.1 ksi

Yield Strength (0.2% offset)

55 MPa8 ksi
120 MPa17.4 ksi

Elongation at Break

8%
12%

Shear Strength

100 MPa14.5 ksi
105 MPa15.2 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
55 MPa8 ksi

Hardness, Brinell

45 HB
50 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 574°C1,065 °F · Liquidus Temperature 632°C1,170 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
163 W/m·K94.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22 µm/m·K12.2 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
42 % IACS

Electrical Resistivity

4.3×10⁻⁸ Ω·m1.69 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Formability (cold)

45 / 100
70 / 100

Same in both: Weldability 95 / 100 · Castability 85 / 100 · Brazeability / Solderability 80 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale4043

4043-AW vs 4043-F — frequently asked

Is 4043-F stronger than 4043-AW?

Yes. 4043-F has a typical yield strength of 120 MPa (17.4 ksi) against 55 MPa (7.98 ksi) for 4043-AW — about 118% more. Tensile strength is 180 MPa (26.1 ksi) vs 165 MPa (23.9 ksi).

Which condition does FabDigit quote by default, AW or F?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 4043-AW or 4043-F?

4043-F, by a small margin. Both rate poor for machinability — 30/100 against 25/100 for 4043-AW.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4043-AW and 4043-F side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.