FabDigitFabDigit

Aluminum 4015-H111 vs 4015-H22

Aluminum · 4015 temper comparison

4015-H111 and 4015-H22 are two conditions of the same aluminum grade, 4015: H111 (slightly strain hardened) versus H22 (strain hardened and partially annealed, quarter hard). The chemistry is identical, so every difference below comes from the condition. 4015-H22 is the stronger of the two: yield strength 110 MPa (16 ksi) against 60 MPa (8.7 ksi) for 4015-H111, about 83% more; tensile strength follows at 145 MPa (21 ksi) vs 125 MPa (18.1 ksi). In exchange, 4015-H111 is the more ductile: elongation 23% versus 12% for 4015-H22, and 4015-H22 is harder (39 HB vs 33 HB). 4015-H111 runs hotter in service (150°C vs 130°C continuous).

4015-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4015-H22Choose it when strength drives the design.

4015-H111 vs 4015-H22: properties

4015-H1114015-H22

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

125 MPa18.1 ksi
145 MPa21 ksi

Yield Strength (0.2% offset)

60 MPa8.7 ksi
110 MPa16 ksi

Elongation at Break

23%
12%

Shear Strength

80 MPa11.6 ksi
90 MPa13.1 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
55 MPa8 ksi

Hardness, Brinell

33 HB
39 HB

Hardness, Vickers

36 HV
43 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 73 GPa10.6 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 630°C1,166 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

164 W/m·K94.8 BTU/hr·ft·°F
163 W/m·K94.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
130°C266 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

43 % IACS
42.5 % IACS

Electrical Resistivity

4×10⁻⁸ Ω·m1.57 µΩ·in
4.06×10⁻⁸ Ω·m1.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

64 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.76 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Weldability

88 / 100
82 / 100

Formability (cold)

87 / 100
78 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 90 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale4015

4015-H111 vs 4015-H22 — frequently asked

Is 4015-H22 stronger than 4015-H111?

Yes. 4015-H22 has a typical yield strength of 110 MPa (16 ksi) against 60 MPa (8.7 ksi) for 4015-H111 — about 83% more. Tensile strength is 145 MPa (21 ksi) vs 125 MPa (18.1 ksi).

Which condition does FabDigit quote by default, H111 or H22?

O is the default 4015 condition in the FabDigit quote flow (neither H111 nor H22). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4015-H111 or 4015-H22?

4015-H22. Its machinability rates fair (42/100) against poor (34/100) for 4015-H111; for welding the order is 4015-H111 first (excellent, 88/100) then 4015-H22 (very good, 82/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4015-H111 and 4015-H22 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.