FabDigitFabDigit

Aluminum 392.0-F vs 392.0-T6

Aluminum · 392.0 temper comparison

392.0-F and 392.0-T6 are two conditions of the same aluminum grade, 392.0: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 392.0-T6 is the stronger of the two: yield strength 310 MPa (45 ksi) against 255 MPa (37 ksi) for 392.0-F, about 22% more; tensile strength follows at 330 MPa (47.9 ksi) vs 290 MPa (42.1 ksi). In exchange, 392.0-F is the more ductile: elongation 0.8% versus 0.5% for 392.0-T6, and 392.0-T6 is harder (125 HB vs 100 HB).

392.0-FChoose it when the part is bent, formed or impact-loaded.

392.0-T6Choose it when strength drives the design.

392.0-F vs 392.0-T6: properties

392.0-F392.0-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

290 MPa42.1 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
310 MPa45 ksi

Elongation at Break

0.8%
0.5%

Shear Strength

185 MPa26.8 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
135 MPa19.6 ksi

Charpy V-Notch Impact (RT)

2 J1.1 ft·lbf
1 J0.74 ft·lbf

Hardness, Brinell

100 HB
125 HB

Hardness, Vickers

108 HV
133 HV

Same in both: Elastic (Young's) Modulus 82 GPa11.9 Msi · Shear Modulus 31 GPa4.5 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.64 g/cm³0.1 lb/in³ · Melting Point (Solidus) 574°C1,065 °F · Liquidus Temperature 649°C1,200 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

134 W/m·K77.4 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.8 µm/m·K9.9 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -195°C-319 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
25 % IACS

Electrical Resistivity

6.6×10⁻⁸ Ω·m2.6 µΩ·in
6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
53 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
33%

Weldability

20 / 100
18 / 100

Formability (cold)

5 / 100
3 / 100

Same in both: Castability 75 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale392.0

392.0-F vs 392.0-T6 — frequently asked

Is 392.0-T6 stronger than 392.0-F?

Yes. 392.0-T6 has a typical yield strength of 310 MPa (45 ksi) against 255 MPa (37 ksi) for 392.0-F — about 22% more. Tensile strength is 330 MPa (47.9 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, F or T6?

F is the default 392.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 392.0-F over 392.0-T6?

Pick 392.0-F when the part is bent, formed or impact-loaded. Pick 392.0-T6 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 392.0-F and 392.0-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.