331.0-F and 331.0-T6 are two conditions of the same aluminum grade, 331.0: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 331.0-T6 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 110 MPa (16 ksi) for 331.0-F, about 77% more; tensile strength follows at 250 MPa (36.3 ksi) vs 165 MPa (23.9 ksi). In exchange, 331.0-F is the more ductile: elongation 1.5% versus 1% for 331.0-T6, and 331.0-T6 is harder (95 HB vs 70 HB). 331.0-T6 runs hotter in service (200°C vs 150°C continuous) and 331.0-F conducts electricity better (30 % IACS vs 26 % IACS).

331.0-FChoose it when the part is bent, formed or impact-loaded.

331.0-T6Choose it when strength drives the design, or when the part sees heat.

331.0-F vs 331.0-T6: properties

331.0-F331.0-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

165 MPa23.9 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
195 MPa28.3 ksi

Elongation at Break

1.5%
1%

Shear Strength

130 MPa18.9 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
90 MPa13.1 ksi

Hardness, Brinell

70 HB
95 HB

Same in both: Elastic (Young's) Modulus 79 GPa11.5 Msi · Shear Modulus 30 GPa4.4 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 538°C1,000 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

117 W/m·K67.6 BTU/hr·ft·°F
110 W/m·K63.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.3 µm/m·K10.7 µin/in·°F · Latent Heat of Fusion 460 J/g198 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
26 % IACS

Same in both: Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V · Corrosion Resistance 42 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 40% · Weldability 35 / 100 · Formability (cold) 5 / 100 · Castability 90 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale331.0

331.0-F vs 331.0-T6 — frequently asked

Is 331.0-T6 stronger than 331.0-F?

Yes. 331.0-T6 has a typical yield strength of 195 MPa (28.3 ksi) against 110 MPa (16 ksi) for 331.0-F — about 77% more. Tensile strength is 250 MPa (36.3 ksi) vs 165 MPa (23.9 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default 331.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 331.0-F or 331.0-T6?

331.0-F, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for 331.0-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 331.0-F and 331.0-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.