FabDigitFabDigit

Aluminum 3203-H111 vs 3203-H112

Aluminum · 3203 temper comparison

3203-H111 and 3203-H112 are two conditions of the same aluminum grade, 3203: H111 (slightly strain hardened) versus H112 (strain hardened from hot working only). The chemistry is identical, so every difference below comes from the condition. 3203-H112 is the stronger of the two: yield strength 60 MPa (8.7 ksi) against 50 MPa (7.25 ksi) for 3203-H111, about 20% more. In exchange, 3203-H111 is the more ductile: elongation 28% versus 22% for 3203-H112, and 3203-H112 is harder (32 HB vs 30 HB). 3203-H111 runs hotter in service (200°C vs 180°C continuous).

3203-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

3203-H112Choose it when strength drives the design.

3203-H111 vs 3203-H112: properties

3203-H1113203-H112

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

115 MPa16.7 ksi
120 MPa17.4 ksi

Yield Strength (0.2% offset)

50 MPa7.3 ksi
60 MPa8.7 ksi

Elongation at Break

28%
22%

Shear Strength

76 MPa11 ksi
79 MPa11.5 ksi

Fatigue Strength (Endurance Limit)

48 MPa7 ksi
50 MPa7.3 ksi

Hardness, Brinell

30 HB
32 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 643°C1,189 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

190 W/m·K110 BTU/hr·ft·°F
182 W/m·K105 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
180°C356 °F

Same in both: Specific Heat Capacity 893 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

49 % IACS
47 % IACS

Electrical Resistivity

3.52×10⁻⁸ Ω·m1.39 µΩ·in
3.67×10⁻⁸ Ω·m1.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
75%

Weldability

90 / 100
88 / 100

Formability (cold)

90 / 100
85 / 100

Same in both: Brazeability / Solderability 92 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale3203

3203-H111 vs 3203-H112 — frequently asked

Is 3203-H112 stronger than 3203-H111?

Yes. 3203-H112 has a typical yield strength of 60 MPa (8.7 ksi) against 50 MPa (7.25 ksi) for 3203-H111 — about 20% more. Tensile strength is 120 MPa (17.4 ksi) vs 115 MPa (16.7 ksi).

Which condition does FabDigit quote by default, H111 or H112?

H14 is the default 3203 condition in the FabDigit quote flow (neither H111 nor H112). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 3203-H111 over 3203-H112?

Pick 3203-H111 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 3203-H112 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3203-H111 and 3203-H112 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.