FabDigitFabDigit

Aluminum 3104-H34 vs 3104-O

Aluminum · 3104 temper comparison

3104-H34 and 3104-O are two conditions of the same aluminum grade, 3104: H34 (strain hardened and stabilized, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 3104-H34 is the stronger of the two: yield strength 200 MPa (29 ksi) against 70 MPa (10.2 ksi) for 3104-O, about 186% more; tensile strength follows at 240 MPa (34.8 ksi) vs 175 MPa (25.4 ksi). In exchange, 3104-O is the more ductile: elongation 24% versus 10% for 3104-H34, and 3104-H34 is harder (63 HB vs 45 HB). 3104-O runs hotter in service (200°C vs 125°C continuous).

3104-H34Choose it when strength drives the design.

3104-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

3104-H34 vs 3104-O: properties

3104-H343104-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

240 MPa34.8 ksi
175 MPa25.4 ksi

Yield Strength (0.2% offset)

200 MPa29 ksi
70 MPa10.2 ksi

Elongation at Break

10%
24%

Shear Strength

145 MPa21 ksi
110 MPa16 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
95 MPa13.8 ksi

Hardness, Brinell

63 HB
45 HB

Hardness, Vickers

69 HV
90 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 629°C1,164 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

162 W/m·K93.6 BTU/hr·ft·°F
163 W/m·K94.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

125°C257 °F
200°C392 °F

Same in both: Specific Heat Capacity 893 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 396 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
4.2×10⁻⁸ Ω·m1.65 µΩ·in

Same in both: Electrical Conductivity 42 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

31 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

27%
30%

Formability (cold)

64 / 100
92 / 100

Same in both: Weldability 85 / 100 · Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale3104

3104-H34 vs 3104-O — frequently asked

Is 3104-H34 stronger than 3104-O?

Yes. 3104-H34 has a typical yield strength of 200 MPa (29 ksi) against 70 MPa (10.2 ksi) for 3104-O — about 186% more. Tensile strength is 240 MPa (34.8 ksi) vs 175 MPa (25.4 ksi).

Which condition does FabDigit quote by default, H34 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 3104-H34 or 3104-O?

3104-H34, by a small margin. Both rate poor for machinability — 31/100 against 25/100 for 3104-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3104-H34 and 3104-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.