FabDigitFabDigit

Aluminum 2A70-F vs 2A70-T4

Aluminum · 2A70 temper comparison

2A70-F and 2A70-T4 are two conditions of the same aluminum grade, 2A70: F (as fabricated) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. 2A70-T4 is the stronger of the two: yield strength 205 MPa (29.7 ksi) against 160 MPa (23.2 ksi) for 2A70-F, about 28% more; tensile strength follows at 350 MPa (50.8 ksi) vs 280 MPa (40.6 ksi). 2A70-T4 is the more ductile: elongation 18% versus 15% for 2A70-F, and 2A70-T4 is harder (95 HB vs 80 HB). 2A70-F runs hotter in service (150°C vs 100°C continuous) and 2A70-F conducts heat better (160 W/m·K vs 130 W/m·K).

2A70-FChoose it when the part sees heat.

2A70-T4Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

2A70-F vs 2A70-T4: properties

2A70-F2A70-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

280 MPa40.6 ksi
350 MPa50.8 ksi

Yield Strength (0.2% offset)

160 MPa23.2 ksi
205 MPa29.7 ksi

Elongation at Break

15%
18%

Reduction in Area

28%
30%

Compressive Strength

165 MPa23.9 ksi
210 MPa30.5 ksi

Shear Strength

180 MPa26.1 ksi
225 MPa32.6 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
110 MPa16 ksi

Fracture Toughness (K_IC)

35 MPa·√m31.9 ksi·√in
32 MPa·√m29.1 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

80 HB
95 HB

Hardness, Vickers

85 HV
102 HV

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27.5 GPa4 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.8 g/cm³0.1 lb/in³ · Melting Point (Solidus) 505°C941 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
100°C212 °F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.3 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
33 % IACS

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
30 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.68 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
50%

Weldability

25 / 100
22 / 100

Formability (cold)

40 / 100
45 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2A70

2A70-F vs 2A70-T4 — frequently asked

Is 2A70-T4 stronger than 2A70-F?

Yes. 2A70-T4 has a typical yield strength of 205 MPa (29.7 ksi) against 160 MPa (23.2 ksi) for 2A70-F — about 28% more. Tensile strength is 350 MPa (50.8 ksi) vs 280 MPa (40.6 ksi).

Which condition does FabDigit quote by default, F or T4?

T6 is the default 2A70 condition in the FabDigit quote flow (neither F nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2A70-F or 2A70-T4?

2A70-T4, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 2A70-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2A70-F and 2A70-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.