2A12-H112 and 2A12-T6 are two conditions of the same aluminum grade, 2A12: H112 (strain hardened from hot working only) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 2A12-T6 is the stronger of the two: yield strength 395 MPa (57.3 ksi) against 150 MPa (21.8 ksi) for 2A12-H112, about 163% more; tensile strength follows at 475 MPa (68.9 ksi) vs 260 MPa (37.7 ksi). In exchange, 2A12-H112 is the more ductile: elongation 12% versus 10% for 2A12-T6, and 2A12-T6 is harder (125 HB vs 70 HB). On the shop floor, 2A12-T6 machines more easily (very good vs good).

2A12-H112Choose it when the part is bent, formed or impact-loaded.

2A12-T6Choose it when strength drives the design, or when the part is machined in volume.

2A12-H112 vs 2A12-T6: properties

2A12-H1122A12-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
475 MPa68.9 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
395 MPa57.3 ksi

Elongation at Break

12%
10%

Reduction in Area

30%
25%

Compressive Strength

150 MPa21.8 ksi
325 MPa47.1 ksi

Shear Strength

165 MPa23.9 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
124 MPa18 ksi

Hardness, Brinell

70 HB
125 HB

Hardness, Rockwell B

35 HRB
75 HRB

Hardness, Vickers

75 HV
128 HV

Same in both: Elastic (Young's) Modulus 73 GPa10.6 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 37 MPa·√m33.7 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 502°C936 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

162 W/m·K93.6 BTU/hr·ft·°F
151 W/m·K87.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
38 % IACS

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
30 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.69 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
76 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
70%

Weldability

20 / 100
15 / 100

Formability (cold)

60 / 100
25 / 100

Same in both: Castability 20 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 13.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2A12

2A12-H112 vs 2A12-T6 — frequently asked

Is 2A12-T6 stronger than 2A12-H112?

Yes. 2A12-T6 has a typical yield strength of 395 MPa (57.3 ksi) against 150 MPa (21.8 ksi) for 2A12-H112 — about 163% more. Tensile strength is 475 MPa (68.9 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, H112 or T6?

T4 is the default 2A12 condition in the FabDigit quote flow (neither H112 nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2A12-H112 or 2A12-T6?

2A12-T6. Its machinability rates very good (76/100) against good (55/100) for 2A12-H112; for welding the order is 2A12-H112 first (poor, 20/100) then 2A12-T6 (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2A12-H112 and 2A12-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.