FabDigitFabDigit

Aluminum 2618-O vs 2618-T6

Aluminum · 2618 temper comparison

2618-O and 2618-T6 are two conditions of the same aluminum grade, 2618: O (annealed) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 2618-T6 is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 125 MPa (18.1 ksi) for 2618-O, about 196% more; tensile strength follows at 440 MPa (63.8 ksi) vs 215 MPa (31.2 ksi). In exchange, 2618-O is the more ductile: elongation 18% versus 9% for 2618-T6, and 2618-T6 is harder (115 HB vs 65 HB). 2618-T6 runs hotter in service (200°C vs 150°C continuous). On the shop floor, 2618-T6 machines more easily (good vs fair).

2618-OChoose it when the part is bent, formed or impact-loaded.

2618-T6Choose it when strength drives the design, or when the part sees heat.

2618-O vs 2618-T6: properties

2618-O2618-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
440 MPa63.8 ksi

Yield Strength (0.2% offset)

125 MPa18.1 ksi
370 MPa53.7 ksi

Elongation at Break

18%
9%

Shear Strength

145 MPa21 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
125 MPa18.1 ksi

Hardness, Brinell

65 HB
115 HB

Same in both: Elastic (Young's) Modulus 74.5 GPa10.8 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33 · Reduction in Area 20% · Compressive Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 28 MPa·√m25.5 ksi·√in · Hardness, Rockwell B 70 HRB · Hardness, Vickers 125 HV

Physical

Density and transition temperatures.

Same in both: Density 2.76 g/cm³0.1 lb/in³ · Melting Point (Solidus) 549°C1,020 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
146 W/m·K84.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.3 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
37 % IACS

Same in both: Electrical Resistivity 4.66×10⁻⁸ Ω·m1.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.7 V · Corrosion Resistance 32 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
65 / 100

Formability (cold)

70 / 100
25 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 150% · Weldability 22 / 100 · Castability 20 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2618

2618-O vs 2618-T6 — frequently asked

Is 2618-T6 stronger than 2618-O?

Yes. 2618-T6 has a typical yield strength of 370 MPa (53.7 ksi) against 125 MPa (18.1 ksi) for 2618-O — about 196% more. Tensile strength is 440 MPa (63.8 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, O or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 2618-O or 2618-T6?

2618-T6. Its machinability rates good (65/100) against fair (40/100) for 2618-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2618-O and 2618-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.