FabDigitFabDigit

Aluminum 2198-O vs 2198-T351

Aluminum · 2198 temper comparison

2198-O and 2198-T351 are two conditions of the same aluminum grade, 2198: O (annealed) versus T351 (T3, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. 2198-T351 is the stronger of the two: yield strength 280 MPa (40.6 ksi) against 130 MPa (18.9 ksi) for 2198-O, about 115% more; tensile strength follows at 405 MPa (58.7 ksi) vs 250 MPa (36.3 ksi). In exchange, 2198-O is the more ductile: elongation 22% versus 18% for 2198-T351, and 2198-T351 is harder (115 HB vs 70 HB). 2198-O conducts heat better (125 W/m·K vs 85 W/m·K). On the shop floor, 2198-T351 machines more easily (good vs fair).

2198-OChoose it when the part is bent, formed or impact-loaded.

2198-T351Choose it when strength drives the design, or when the part is machined in volume.

2198-O vs 2198-T351: properties

2198-O2198-T351

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
405 MPa58.7 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
280 MPa40.6 ksi

Elongation at Break

22%
18%

Shear Strength

160 MPa23.2 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
138 MPa20 ksi

Fracture Toughness (K_IC)

38 MPa·√m34.6 ksi·√in
45 MPa·√m41 ksi·√in

Hardness, Brinell

70 HB
115 HB

Same in both: Elastic (Young's) Modulus 76 GPa11 Msi · Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 74 GPa10.7 Msi · Poisson's Ratio 0.33 · Compressive Strength 440 MPa63.8 ksi · Hardness, Rockwell B 80 HRB · Hardness, Vickers 155 HV

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 560°C1,040 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
85 W/m·K49.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23 µm/m·K12.8 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

35 % IACS
23 % IACS

Same in both: Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
40 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.73 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
58 / 100

Formability (cold)

80 / 100
55 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 55% · Weldability 30 / 100 · Castability 25 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 215 MJ/kg92,433 BTU/lb · Embodied Carbon (primary production) 13.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2198

2198-O vs 2198-T351 — frequently asked

Is 2198-T351 stronger than 2198-O?

Yes. 2198-T351 has a typical yield strength of 280 MPa (40.6 ksi) against 130 MPa (18.9 ksi) for 2198-O — about 115% more. Tensile strength is 405 MPa (58.7 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, O or T351?

T8 is the default 2198 condition in the FabDigit quote flow (neither O nor T351). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2198-O or 2198-T351?

2198-T351. Its machinability rates good (58/100) against fair (40/100) for 2198-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2198-O and 2198-T351 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.