FabDigitFabDigit

Aluminum 2091-O vs 2091-T351

Aluminum · 2091 temper comparison

2091-O and 2091-T351 are two conditions of the same aluminum grade, 2091: O (annealed) versus T351 (T3, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. 2091-T351 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 145 MPa (21 ksi) for 2091-O, about 72% more; tensile strength follows at 400 MPa (58 ksi) vs 260 MPa (37.7 ksi). In exchange, 2091-O is the more ductile: elongation 22% versus 18% for 2091-T351, and 2091-T351 is harder (103 HB vs 65 HB). 2091-O conducts heat better (115 W/m·K vs 85 W/m·K). On the shop floor, 2091-T351 machines more easily (good vs fair).

2091-OChoose it when the part is bent, formed or impact-loaded.

2091-T351Choose it when strength drives the design, or when the part is machined in volume.

2091-O vs 2091-T351: properties

2091-O2091-T351

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
250 MPa36.3 ksi

Elongation at Break

22%
18%

Shear Strength

160 MPa23.2 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
135 MPa19.6 ksi

Fracture Toughness (K_IC)

37 MPa·√m33.7 ksi·√in
42 MPa·√m38.2 ksi·√in

Hardness, Brinell

65 HB
103 HB

Same in both: Elastic (Young's) Modulus 75 GPa10.9 Msi · Shear Modulus 28.5 GPa4.1 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 2.58 g/cm³0.09 lb/in³ · Melting Point (Solidus) 560°C1,040 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

115 W/m·K66.4 BTU/hr·ft·°F
85 W/m·K49.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 860 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23 µm/m·K12.8 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 100°C212 °F · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

23 % IACS
17 % IACS

Electrical Resistivity

7.5×10⁻⁸ Ω·m2.95 µΩ·in
1.01×10⁻⁷ Ω·m3.98 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

38 / 100
28 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.72 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
63 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
50%

Formability (cold)

75 / 100
48 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 10 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 225 MJ/kg96,733 BTU/lb · Embodied Carbon (primary production) 14.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2091

2091-O vs 2091-T351 — frequently asked

Is 2091-T351 stronger than 2091-O?

Yes. 2091-T351 has a typical yield strength of 250 MPa (36.3 ksi) against 145 MPa (21 ksi) for 2091-O — about 72% more. Tensile strength is 400 MPa (58 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, O or T351?

T8X is the default 2091 condition in the FabDigit quote flow (neither O nor T351). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2091-O or 2091-T351?

2091-T351. Its machinability rates good (63/100) against fair (45/100) for 2091-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2091-O and 2091-T351 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.