FabDigitFabDigit

Aluminum 2008-T4P vs 2008-T6

Aluminum · 2008 temper comparison

2008-T4P and 2008-T6 are two conditions of the same aluminum grade, 2008: T4P (solution heat treated, pre-aged/stabilized for controlled natural ageing) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 2008-T6 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 120 MPa (17.4 ksi) for 2008-T4P, about 129% more; tensile strength follows at 315 MPa (45.7 ksi) vs 235 MPa (34.1 ksi). In exchange, 2008-T4P is the more ductile: elongation 29% versus 12% for 2008-T6, and 2008-T6 is harder (95 HB vs 63 HB). 2008-T6 runs hotter in service (150°C vs 100°C continuous).

2008-T4PChoose it when the part is bent, formed or impact-loaded.

2008-T6Choose it when strength drives the design, or when the part sees heat.

2008-T4P vs 2008-T6: properties

2008-T4P2008-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

235 MPa34.1 ksi
315 MPa45.7 ksi

Yield Strength (0.2% offset)

120 MPa17.4 ksi
275 MPa39.9 ksi

Elongation at Break

29%
12%

Shear Strength

145 MPa21 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

88 MPa12.8 ksi
110 MPa16 ksi

Hardness, Brinell

63 HB
95 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 560°C1,040 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

190 W/m·K110 BTU/hr·ft·°F
200 W/m·K116 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

43 % IACS
46 % IACS

Electrical Resistivity

4×10⁻⁸ Ω·m1.57 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
35 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.69 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
50%

Formability (cold)

87 / 100
35 / 100

Same in both: Weldability 35 / 100 · Brazeability / Solderability 15 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2008

2008-T4P vs 2008-T6 — frequently asked

Is 2008-T6 stronger than 2008-T4P?

Yes. 2008-T6 has a typical yield strength of 275 MPa (39.9 ksi) against 120 MPa (17.4 ksi) for 2008-T4P — about 129% more. Tensile strength is 315 MPa (45.7 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, T4P or T6?

T4 is the default 2008 condition in the FabDigit quote flow (neither T4P nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2008-T4P or 2008-T6?

2008-T6. Its machinability rates good (55/100) against fair (50/100) for 2008-T4P.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2008-T4P and 2008-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.