FabDigitFabDigit

Aluminum 1350-H14 vs 1350-O

Aluminum · 1350 temper comparison

1350-H14 and 1350-O are two conditions of the same aluminum grade, 1350: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1350-H14 is the stronger of the two: yield strength 97 MPa (14.1 ksi) against 28 MPa (4.06 ksi) for 1350-O, about 3.5 times as much; tensile strength follows at 110 MPa (16 ksi) vs 83 MPa (12 ksi). In exchange, 1350-O is the more ductile: elongation 23% versus 9% for 1350-H14, and 1350-H14 is harder (32 HB vs 20 HB). 1350-O runs hotter in service (200°C vs 110°C continuous). On the shop floor, 1350-H14 machines more easily (fair vs poor).

1350-H14Choose it when strength drives the design, or when the part is machined in volume.

1350-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1350-H14 vs 1350-O: properties

1350-H141350-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
83 MPa12 ksi

Yield Strength (0.2% offset)

97 MPa14.1 ksi
28 MPa4.1 ksi

Elongation at Break

9%
23%

Shear Strength

69 MPa10 ksi
55 MPa8 ksi

Fatigue Strength (Endurance Limit)

41 MPa5.9 ksi
34 MPa4.9 ksi

Hardness, Brinell

32 HB
20 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

230 W/m·K133 BTU/hr·ft·°F
234 W/m·K135 BTU/hr·ft·°F

Max Service Temperature (continuous)

110°C230 °F
200°C392 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.8 % IACS
62 % IACS

Electrical Resistivity

2.79×10⁻⁸ Ω·m1.1 µΩ·in
2.78×10⁻⁸ Ω·m1.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
25 / 100

Formability (cold)

70 / 100
95 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 90% · Weldability 90 / 100 · Brazeability / Solderability 85 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 8%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1350

1350-H14 vs 1350-O — frequently asked

Is 1350-H14 stronger than 1350-O?

Yes. 1350-H14 has a typical yield strength of 97 MPa (14.1 ksi) against 28 MPa (4.06 ksi) for 1350-O — about 3.5 times as much. Tensile strength is 110 MPa (16 ksi) vs 83 MPa (12 ksi).

Which condition does FabDigit quote by default, H14 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1350-H14 or 1350-O?

1350-H14. Its machinability rates fair (35/100) against poor (25/100) for 1350-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1350-H14 and 1350-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.