FabDigitFabDigit

Aluminum 1230-H19 vs 1230-O

Aluminum · 1230 temper comparison

1230-H19 and 1230-O are two conditions of the same aluminum grade, 1230: H19 (strain hardened, extra hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1230-H19 is the stronger of the two: yield strength 155 MPa (22.5 ksi) against 28 MPa (4.06 ksi) for 1230-O, about 5.5 times as much; tensile strength follows at 165 MPa (23.9 ksi) vs 80 MPa (11.6 ksi). In exchange, 1230-O is the more ductile: elongation 38% versus 2.5% for 1230-H19, and 1230-H19 is harder (40 HB vs 20 HB). 1230-O runs hotter in service (150°C vs 100°C continuous). On the shop floor, 1230-H19 machines more easily (fair vs poor).

1230-H19Choose it when strength drives the design, or when the part is machined in volume.

1230-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1230-H19 vs 1230-O: properties

1230-H191230-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

165 MPa23.9 ksi
80 MPa11.6 ksi

Yield Strength (0.2% offset)

155 MPa22.5 ksi
28 MPa4.1 ksi

Elongation at Break

2.5%
38%

Shear Strength

85 MPa12.3 ksi
50 MPa7.3 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
30 MPa4.4 ksi

Hardness, Brinell

40 HB
20 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

226 W/m·K131 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

59 % IACS
61 % IACS

Electrical Resistivity

2.92×10⁻⁸ Ω·m1.15 µΩ·in
2.83×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

80 / 100
82 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
25%

Weldability

85 / 100
92 / 100

Formability (cold)

30 / 100
98 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 70 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1230

1230-H19 vs 1230-O — frequently asked

Is 1230-H19 stronger than 1230-O?

Yes. 1230-H19 has a typical yield strength of 155 MPa (22.5 ksi) against 28 MPa (4.06 ksi) for 1230-O — about 5.5 times as much. Tensile strength is 165 MPa (23.9 ksi) vs 80 MPa (11.6 ksi).

Which condition does FabDigit quote by default, H19 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1230-H19 or 1230-O?

1230-H19. Its machinability rates fair (38/100) against poor (22/100) for 1230-O; for welding the order is 1230-O first (excellent, 92/100) then 1230-H19 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1230-H19 and 1230-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.