FabDigitFabDigit

Aluminum 1230-F vs 1230-H19

Aluminum · 1230 temper comparison

1230-F and 1230-H19 are two conditions of the same aluminum grade, 1230: F (as fabricated) versus H19 (strain hardened, extra hard). The chemistry is identical, so every difference below comes from the condition. 1230-H19 is the stronger of the two: yield strength 155 MPa (22.5 ksi) against 35 MPa (5.08 ksi) for 1230-F, about 4.4 times as much; tensile strength follows at 165 MPa (23.9 ksi) vs 85 MPa (12.3 ksi). In exchange, 1230-F is the more ductile: elongation 30% versus 2.5% for 1230-H19, and 1230-H19 is harder (40 HB vs 22 HB). 1230-F runs hotter in service (150°C vs 100°C continuous). On the shop floor, 1230-H19 machines more easily (fair vs poor).

1230-FChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1230-H19Choose it when strength drives the design, or when the part is machined in volume.

1230-F vs 1230-H19: properties

1230-F1230-H19

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

85 MPa12.3 ksi
165 MPa23.9 ksi

Yield Strength (0.2% offset)

35 MPa5.1 ksi
155 MPa22.5 ksi

Elongation at Break

30%
2.5%

Shear Strength

55 MPa8 ksi
85 MPa12.3 ksi

Fatigue Strength (Endurance Limit)

30 MPa4.4 ksi
50 MPa7.3 ksi

Hardness, Brinell

22 HB
40 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

231 W/m·K133 BTU/hr·ft·°F
226 W/m·K131 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
100°C212 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61 % IACS
59 % IACS

Electrical Resistivity

2.83×10⁻⁸ Ω·m1.11 µΩ·in
2.92×10⁻⁸ Ω·m1.15 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

82 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
32%

Weldability

92 / 100
85 / 100

Formability (cold)

95 / 100
30 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 70 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1230

1230-F vs 1230-H19 — frequently asked

Is 1230-H19 stronger than 1230-F?

Yes. 1230-H19 has a typical yield strength of 155 MPa (22.5 ksi) against 35 MPa (5.08 ksi) for 1230-F — about 4.4 times as much. Tensile strength is 165 MPa (23.9 ksi) vs 85 MPa (12.3 ksi).

Which condition does FabDigit quote by default, F or H19?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1230-F or 1230-H19?

1230-H19. Its machinability rates fair (38/100) against poor (28/100) for 1230-F; for welding the order is 1230-F first (excellent, 92/100) then 1230-H19 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1230-F and 1230-H19 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.