FabDigitFabDigit

Aluminum 1199-H14 vs 1199-O

Aluminum · 1199 temper comparison

1199-H14 and 1199-O are two conditions of the same aluminum grade, 1199: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1199-H14 is the stronger of the two: yield strength 70 MPa (10.2 ksi) against 12 MPa (1.74 ksi) for 1199-O, about 5.8 times as much; tensile strength follows at 80 MPa (11.6 ksi) vs 45 MPa (6.53 ksi). In exchange, 1199-O is the more ductile: elongation 50% versus 10% for 1199-H14, and 1199-H14 is harder (23 HB vs 13 HB). 1199-O runs hotter in service (150°C vs 100°C continuous).

1199-H14Choose it when strength drives the design.

1199-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1199-H14 vs 1199-O: properties

1199-H141199-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

80 MPa11.6 ksi
45 MPa6.5 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
12 MPa1.7 ksi

Elongation at Break

10%
50%

Shear Strength

50 MPa7.3 ksi
35 MPa5.1 ksi

Fatigue Strength (Endurance Limit)

30 MPa4.4 ksi
20 MPa2.9 ksi

Hardness, Brinell

23 HB
13 HB

Hardness, Vickers

26 HV
16 HV

Same in both: Elastic (Young's) Modulus 62 GPa9 Msi · Shear Modulus 25 GPa3.6 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 660°C1,220 °F · Liquidus Temperature 660°C1,221 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

241 W/m·K139 BTU/hr·ft·°F
243 W/m·K140 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

64 % IACS
64.5 % IACS

Electrical Resistivity

2.69×10⁻⁸ Ω·m1.06 µΩ·in
2.67×10⁻⁸ Ω·m1.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V · Corrosion Resistance 82 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
20 / 100

Weldability

88 / 100
90 / 100

Formability (cold)

75 / 100
98 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Castability 45 / 100 · Brazeability / Solderability 88 / 100 · Polishability 95 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 230 MJ/kg98,882 BTU/lb · Embodied Carbon (primary production) 14 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1199

1199-H14 vs 1199-O — frequently asked

Is 1199-H14 stronger than 1199-O?

Yes. 1199-H14 has a typical yield strength of 70 MPa (10.2 ksi) against 12 MPa (1.74 ksi) for 1199-O — about 5.8 times as much. Tensile strength is 80 MPa (11.6 ksi) vs 45 MPa (6.53 ksi).

Which condition does FabDigit quote by default, H14 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1199-H14 or 1199-O?

1199-H14, by a small margin. Both rate poor for machinability — 25/100 against 20/100 for 1199-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1199-H14 and 1199-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.