FabDigitFabDigit

Aluminum 1145-H14 vs 1145-O

Aluminum · 1145 temper comparison

1145-H14 and 1145-O are two conditions of the same aluminum grade, 1145: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1145-H14 is the stronger of the two: yield strength 95 MPa (13.8 ksi) against 25 MPa (3.63 ksi) for 1145-O, about 3.8 times as much; tensile strength follows at 110 MPa (16 ksi) vs 75 MPa (10.9 ksi). In exchange, 1145-O is the more ductile: elongation 35% versus 9% for 1145-H14, and 1145-H14 is harder (32 HB vs 21 HB). 1145-O runs hotter in service (200°C vs 110°C continuous).

1145-H14Choose it when strength drives the design.

1145-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1145-H14 vs 1145-O: properties

1145-H141145-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
75 MPa10.9 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
25 MPa3.6 ksi

Elongation at Break

9%
35%

Shear Strength

70 MPa10.2 ksi
48 MPa7 ksi

Fatigue Strength (Endurance Limit)

48 MPa7 ksi
34 MPa4.9 ksi

Hardness, Brinell

32 HB
21 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

230 W/m·K133 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

110°C230 °F
200°C392 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

60 % IACS
61 % IACS

Electrical Resistivity

2.87×10⁻⁸ Ω·m1.13 µΩ·in
2.83×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
73 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
22 / 100

Formability (cold)

65 / 100
95 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 45% · Weldability 90 / 100 · Castability 35 / 100 · Brazeability / Solderability 60 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1145

1145-H14 vs 1145-O — frequently asked

Is 1145-H14 stronger than 1145-O?

Yes. 1145-H14 has a typical yield strength of 95 MPa (13.8 ksi) against 25 MPa (3.63 ksi) for 1145-O — about 3.8 times as much. Tensile strength is 110 MPa (16 ksi) vs 75 MPa (10.9 ksi).

Which condition does FabDigit quote by default, H14 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1145-H14 or 1145-O?

1145-H14, by a small margin. Both rate poor for machinability — 30/100 against 22/100 for 1145-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1145-H14 and 1145-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.