FabDigitFabDigit

Aluminum 1100A-H12 vs 1100A-O

Aluminum · 1100A temper comparison

1100A-H12 and 1100A-O are two conditions of the same aluminum grade, 1100A: H12 (strain hardened, quarter hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1100A-H12 is the stronger of the two: yield strength 105 MPa (15.2 ksi) against 34 MPa (4.93 ksi) for 1100A-O, about 3.1 times as much; tensile strength follows at 110 MPa (16 ksi) vs 90 MPa (13.1 ksi). In exchange, 1100A-O is the more ductile: elongation 40% versus 12% for 1100A-H12, and 1100A-H12 is harder (28 HB vs 23 HB). 1100A-O runs hotter in service (200°C vs 150°C continuous).

1100A-H12Choose it when strength drives the design.

1100A-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1100A-H12 vs 1100A-O: properties

1100A-H121100A-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
90 MPa13.1 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
34 MPa4.9 ksi

Elongation at Break

12%
40%

Shear Strength

69 MPa10 ksi
62 MPa9 ksi

Fatigue Strength (Endurance Limit)

41 MPa5.9 ksi
34 MPa4.9 ksi

Hardness, Brinell

28 HB
23 HB

Hardness, Vickers

31 HV
25 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 643°C1,189 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Thermal Conductivity 222 W/m·K128 BTU/hr·ft·°F · Specific Heat Capacity 904 J/kg·K0.22 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

57 % IACS
59 % IACS

Electrical Resistivity

3.02×10⁻⁸ Ω·m1.19 µΩ·in
2.92×10⁻⁸ Ω·m1.15 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
25%

Formability (cold)

88 / 100
98 / 100

Same in both: Weldability 95 / 100 · Brazeability / Solderability 85 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1100A

1100A-H12 vs 1100A-O — frequently asked

Is 1100A-H12 stronger than 1100A-O?

Yes. 1100A-H12 has a typical yield strength of 105 MPa (15.2 ksi) against 34 MPa (4.93 ksi) for 1100A-O — about 3.1 times as much. Tensile strength is 110 MPa (16 ksi) vs 90 MPa (13.1 ksi).

Which condition does FabDigit quote by default, H12 or O?

H14 is the default 1100A condition in the FabDigit quote flow (neither H12 nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1100A-H12 or 1100A-O?

1100A-H12, by a small margin. Both rate poor for machinability — 33/100 against 28/100 for 1100A-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1100A-H12 and 1100A-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.