Aluminum 1050A-H111 vs 1050A-H22

Aluminum · 1050A temper comparison

1050A-H111 and 1050A-H22 are two conditions of the same aluminum grade, 1050A: H111 (slightly strain hardened) versus H22 (strain hardened and partially annealed, quarter hard). The chemistry is identical, so every difference below comes from the condition. 1050A-H22 is the stronger of the two: yield strength 70 MPa (10.2 ksi) against 32 MPa (4.64 ksi) for 1050A-H111, about 119% more; tensile strength follows at 100 MPa (14.5 ksi) vs 80 MPa (11.6 ksi). In exchange, 1050A-H111 is the more ductile: elongation 35% versus 14% for 1050A-H22, and 1050A-H22 is harder (26 HB vs 21 HB). 1050A-H111 runs hotter in service (150°C vs 130°C continuous).

1050A-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1050A-H22Choose it when strength drives the design.

1050A-H111 vs 1050A-H22: properties

1050A-H1111050A-H22

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

80 MPa11.6 ksi
100 MPa14.5 ksi

Yield Strength (0.2% offset)

32 MPa4.6 ksi
70 MPa10.2 ksi

Elongation at Break

35%
14%

Shear Strength

52 MPa7.5 ksi
62 MPa9 ksi

Fatigue Strength (Endurance Limit)

25 MPa3.6 ksi
32 MPa4.6 ksi

Hardness, Brinell

21 HB
26 HB

Hardness, Vickers

24 HV
30 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

231 W/m·K133 BTU/hr·ft·°F
230 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
130°C266 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.5 % IACS
61.3 % IACS

Electrical Resistivity

2.8×10⁻⁸ Ω·m1.1 µΩ·in
2.81×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

73 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
29 / 100

Machinability Rating (AISI 1212 = 100 %)

24%
28%

Weldability

92 / 100
91 / 100

Formability (cold)

94 / 100
88 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 70 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1050A

1050A-H111 vs 1050A-H22 — frequently asked

Is 1050A-H22 stronger than 1050A-H111?

Yes. 1050A-H22 has a typical yield strength of 70 MPa (10.2 ksi) against 32 MPa (4.64 ksi) for 1050A-H111 — about 119% more. Tensile strength is 100 MPa (14.5 ksi) vs 80 MPa (11.6 ksi).

Which condition does FabDigit quote by default, H111 or H22?

H14 is the default 1050A condition in the FabDigit quote flow (neither H111 nor H22). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1050A-H111 over 1050A-H22?

Pick 1050A-H111 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1050A-H22 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1050A-H111 and 1050A-H22 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.