FabDigitFabDigit

Titanium IMI 829-ANN vs IMI 829 BETA-STA

Titanium · IMI 829 temper comparison

IMI 829-ANN and IMI 829 BETA-STA are two conditions of the same titanium grade, IMI 829: ANN (annealed) versus BETA-STA (Β-STA). The chemistry is identical, so every difference below comes from the condition. IMI 829 BETA-STA is the stronger of the two: yield strength 865 MPa (125 ksi) against 820 MPa (119 ksi) for IMI 829-ANN, about 5% more; tensile strength follows at 980 MPa (142 ksi) vs 930 MPa (135 ksi). In exchange, IMI 829-ANN is the more ductile: elongation 13% versus 11% for IMI 829 BETA-STA, and IMI 829 BETA-STA is harder (313 HB vs 295 HB). IMI 829 BETA-STA runs hotter in service (580°C vs 500°C continuous).

IMI 829-ANNChoose it when the part is bent, formed or impact-loaded.

IMI 829 BETA-STAChoose it when strength drives the design, or when the part sees heat.

IMI 829-ANN vs IMI 829 BETA-STA: properties

IMI 829-ANNIMI 829 BETA-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

118 GPa17.1 Msi
120 GPa17.4 Msi

Tensile Strength (Ultimate)

930 MPa135 ksi
980 MPa142 ksi

Yield Strength (0.2% offset)

820 MPa119 ksi
865 MPa125 ksi

Elongation at Break

13%
11%

Reduction in Area

25%
20%

Compressive Strength

850 MPa123 ksi
900 MPa131 ksi

Shear Strength

590 MPa85.6 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

470 MPa68.2 ksi
500 MPa72.5 ksi

Fracture Toughness (K_IC)

58 MPa·√m52.8 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

19 J14 ft·lbf
16 J11.8 ft·lbf

Hardness, Brinell

295 HB
313 HB

Hardness, Rockwell C

31 HRC
33 HRC

Hardness, Vickers

310 HV
330 HV

Same in both: Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 4.54 g/cm³0.16 lb/in³ · Melting Point (Solidus) 1,550°C2,822 °F · Liquidus Temperature 1,630°C2,966 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

500°C932 °F
580°C1,076 °F

Same in both: Thermal Conductivity 7 W/m·K4 BTU/hr·ft·°F · Specific Heat Capacity 530 J/kg·K0.13 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 9.5 µm/m·K5.3 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.1 % IACS · Electrical Resistivity 1.6×10⁻⁶ Ω·m63 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
15 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
18%

Weldability

50 / 100
45 / 100

Formability (cold)

25 / 100
20 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 40 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 700 MJ/kg300,946 BTU/lb · Embodied Carbon (primary production) 43 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleIMI 829

IMI 829-ANN vs IMI 829 BETA-STA — frequently asked

Is IMI 829 BETA-STA stronger than IMI 829-ANN?

Yes. IMI 829 BETA-STA has a typical yield strength of 865 MPa (125 ksi) against 820 MPa (119 ksi) for IMI 829-ANN — about 5% more. Tensile strength is 980 MPa (142 ksi) vs 930 MPa (135 ksi).

Which condition does FabDigit quote by default, ANN or BETA-STA?

BETA-STA is the default IMI 829 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, IMI 829-ANN or IMI 829 BETA-STA?

IMI 829-ANN. Its weldability rates fair (50/100) against fair (45/100) for IMI 829 BETA-STA.

Ready to make it?

Upload a CAD file and FabDigit prices the part in IMI 829-ANN and IMI 829 BETA-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.