FabDigitFabDigit

Steel WCB-A vs WCB N+T

Steel · WCB temper comparison

WCB-A and WCB N+T are two conditions of the same steel grade, WCB: A (solution annealed) versus N+T (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. WCB N+T is the stronger of the two: yield strength 285 MPa (41.3 ksi) against 265 MPa (38.4 ksi) for WCB-A, about 8% more. WCB N+T is harder — 145 HB against 135 HB for WCB-A — which matters for wear surfaces and threads.

WCB N+TChoose it when strength drives the design, or when surface hardness matters.

WCB-A vs WCB N+T: properties

WCB-AWCB N+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

495 MPa71.8 ksi
505 MPa73.2 ksi

Yield Strength (0.2% offset)

265 MPa38.4 ksi
285 MPa41.3 ksi

Elongation at Break

31%
29%

Reduction in Area

50%
48%

Compressive Strength

265 MPa38.4 ksi
285 MPa41.3 ksi

Shear Strength

305 MPa44.2 ksi
315 MPa45.7 ksi

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
225 MPa32.6 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

42 J31 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

135 HB
145 HB

Hardness, Rockwell B

74 HRB
78 HRB

Hardness, Vickers

142 HV
152 HV

Same in both: Elastic (Young's) Modulus 202 GPa29.3 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 272 J/g117 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.5 % IACS
10 % IACS

Electrical Resistivity

1.65×10⁻⁷ Ω·m6.5 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
72%

Weldability

85 / 100
82 / 100

Formability (cold)

32 / 100
27 / 100

Same in both: Castability 80 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 24 MJ/kg10,318 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleWCB

WCB-A vs WCB N+T — frequently asked

Is WCB N+T stronger than WCB-A?

Yes. WCB N+T has a typical yield strength of 285 MPa (41.3 ksi) against 265 MPa (38.4 ksi) for WCB-A — about 8% more. Tensile strength is 505 MPa (73.2 ksi) vs 495 MPa (71.8 ksi).

Which condition does FabDigit quote by default, A or N+T?

WCB is the default WCB condition in the FabDigit quote flow (neither A nor N+T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose WCB-A over WCB N+T?

Pick WCB N+T when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in WCB-A and WCB N+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.