FabDigitFabDigit

Steel WC1 A+T vs WC1 Q+T

Steel · WC1 temper comparison

WC1 A+T and WC1 Q+T are two conditions of the same steel grade, WC1: A+T (full annealed and tempered) versus Q+T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. WC1 Q+T is the stronger of the two: yield strength 360 MPa (52.2 ksi) against 275 MPa (39.9 ksi) for WC1 A+T, about 31% more; tensile strength follows at 570 MPa (82.7 ksi) vs 480 MPa (69.6 ksi). In exchange, WC1 A+T is the more ductile: elongation 31% versus 26% for WC1 Q+T, and WC1 Q+T is harder (180 HB vs 149 HB).

WC1 A+TChoose it when the part is bent, formed or impact-loaded.

WC1 Q+TChoose it when strength drives the design.

WC1 A+T vs WC1 Q+T: properties

WC1 A+TWC1 Q+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
360 MPa52.2 ksi

Elongation at Break

31%
26%

Reduction in Area

52%
55%

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

149 HB
180 HB

Hardness, Rockwell B

80 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 300 MPa43.5 ksi · Shear Strength 340 MPa49.3 ksi · Fracture Toughness (K_IC) 130 MPa·√m118 ksi·√in · Hardness, Vickers 168 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 455°C851 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.5 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
54 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
55%

Same in both: Weldability 70 / 100 · Formability (cold) 20 / 100 · Castability 70 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleWC1

WC1 A+T vs WC1 Q+T — frequently asked

Is WC1 Q+T stronger than WC1 A+T?

Yes. WC1 Q+T has a typical yield strength of 360 MPa (52.2 ksi) against 275 MPa (39.9 ksi) for WC1 A+T — about 31% more. Tensile strength is 570 MPa (82.7 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, A+T or Q+T?

N+T is the default WC1 condition in the FabDigit quote flow (neither A+T nor Q+T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, WC1 A+T or WC1 Q+T?

WC1 A+T. Its machinability rates good (62/100) against fair (54/100) for WC1 Q+T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in WC1 A+T and WC1 Q+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.