FabDigitFabDigit

Steel W1 Annealed vs W1 Cold Drawn

Steel · W1 temper comparison

W1 Annealed and W1 Cold Drawn are two conditions of the same steel grade, W1: Annealed versus Cold Drawn. The chemistry is identical, so every difference below comes from the condition. W1 Cold Drawn is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 460 MPa (66.7 ksi) for W1 Annealed, about 35% more; tensile strength follows at 830 MPa (120 ksi) vs 760 MPa (110 ksi). In exchange, W1 Annealed is the more ductile: elongation 22% versus 14% for W1 Cold Drawn, and W1 Cold Drawn is harder (215 HB vs 200 HB). W1 Annealed runs hotter in service (300°C vs 250°C continuous).

W1 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

W1 Cold DrawnChoose it when strength drives the design.

W1 Annealed vs W1 Cold Drawn: properties

W1 AnnealedW1 Cold Drawn

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
830 MPa120 ksi

Yield Strength (0.2% offset)

460 MPa66.7 ksi
620 MPa89.9 ksi

Elongation at Break

22%
14%

Reduction in Area

45%
38%

Compressive Strength

500 MPa72.5 ksi
640 MPa92.8 ksi

Shear Strength

470 MPa68.2 ksi
510 MPa74 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
360 MPa52.2 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

200 HB
215 HB

Hardness, Rockwell B

93 HRB
95 HRB

Hardness, Vickers

210 HV
226 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.83 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
250°C482 °F

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.4 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
47 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Weldability

15 / 100
14 / 100

Formability (cold)

35 / 100
26 / 100

Polishability

75 / 100
78 / 100

Same in both: Brazeability / Solderability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleW1

W1 Annealed vs W1 Cold Drawn — frequently asked

Is W1 Cold Drawn stronger than W1 Annealed?

Yes. W1 Cold Drawn has a typical yield strength of 620 MPa (89.9 ksi) against 460 MPa (66.7 ksi) for W1 Annealed — about 35% more. Tensile strength is 830 MPa (120 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, Annealed or Cold Drawn?

Annealed is the default W1 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose W1 Annealed over W1 Cold Drawn?

Pick W1 Annealed when the part is bent, formed or impact-loaded, or when the part sees heat. Pick W1 Cold Drawn when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in W1 Annealed and W1 Cold Drawn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.