FabDigitFabDigit

Steel T9A-CD vs T9A-N

Steel · T9A temper comparison

T9A-CD and T9A-N are two conditions of the same steel grade, T9A: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. T9A-CD is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 500 MPa (72.5 ksi) for T9A-N, about 24% more. In exchange, T9A-N is the more ductile: elongation 12% versus 10% for T9A-CD, and T9A-N is harder (260 HB vs 235 HB). On the shop floor, T9A-CD machines more easily (52 vs 42 out of 100).

T9A-CDChoose it when strength drives the design, or when the part is machined in volume.

T9A-NChoose it when the part is bent, formed or impact-loaded.

T9A-CD vs T9A-N: properties

T9A-CDT9A-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
880 MPa128 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
500 MPa72.5 ksi

Elongation at Break

10%
12%

Reduction in Area

33%
27%

Compressive Strength

640 MPa92.8 ksi
515 MPa74.7 ksi

Shear Strength

480 MPa69.6 ksi
530 MPa76.9 ksi

Fatigue Strength (Endurance Limit)

360 MPa52.2 ksi
390 MPa56.6 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

235 HB
260 HB

Hardness, Rockwell B

99 HRB
101 HRB

Hardness, Vickers

247 HV
273 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

48 W/m·K27.7 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9.6 % IACS
9.5 % IACS

Electrical Resistivity

1.8×10⁻⁷ Ω·m7.09 µΩ·in
1.82×10⁻⁷ Ω·m7.17 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
45%

Weldability

15 / 100
12 / 100

Formability (cold)

25 / 100
20 / 100

Same in both: Castability 20 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleT9A

T9A-CD vs T9A-N — frequently asked

Is T9A-CD stronger than T9A-N?

Yes. T9A-CD has a typical yield strength of 620 MPa (89.9 ksi) against 500 MPa (72.5 ksi) for T9A-N — about 24% more. Tensile strength is 800 MPa (116 ksi) vs 880 MPa (128 ksi).

Which condition does FabDigit quote by default, CD or N?

A is the default T9A condition in the FabDigit quote flow (neither CD nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, T9A-CD or T9A-N?

T9A-CD, by a small margin. Both rate fair for machinability — 52/100 against 42/100 for T9A-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in T9A-CD and T9A-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.