FabDigitFabDigit

Steel T12A-CD vs T12A-QT200

Steel · T12A temper comparison

T12A-CD and T12A-QT200 are two conditions of the same steel grade, T12A: CD (cold drawn) versus QT200 (water quenched + tempered 180–220 °C). The chemistry is identical, so every difference below comes from the condition. T12A-QT200 is the stronger of the two: yield strength 1,800 MPa (261 ksi) against 700 MPa (102 ksi) for T12A-CD, about 157% more; tensile strength follows at 2,050 MPa (297 ksi) vs 880 MPa (128 ksi). In exchange, T12A-CD is the more ductile: elongation 8% versus 1% for T12A-QT200, and T12A-CD is harder (250 HB vs 200 HB). T12A-CD runs hotter in service (400°C vs 180°C continuous) and T12A-CD conducts heat better (47 W/m·K vs 42 W/m·K). On the shop floor, T12A-CD machines more easily (fair vs not recommended).

T12A-CDChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

T12A-QT200Choose it when strength drives the design.

T12A-CD vs T12A-QT200: properties

T12A-CDT12A-QT200

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

210 GPa30.5 Msi
207 GPa30 Msi

Tensile Strength (Ultimate)

880 MPa128 ksi
2,050 MPa297 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
1,800 MPa261 ksi

Elongation at Break

8%
1%

Reduction in Area

20%
1%

Compressive Strength

720 MPa104 ksi
2,700 MPa392 ksi

Shear Strength

550 MPa79.8 ksi
1,230 MPa178 ksi

Fatigue Strength (Endurance Limit)

390 MPa56.6 ksi
680 MPa98.6 ksi

Fracture Toughness (K_IC)

38 MPa·√m34.6 ksi·√in
16 MPa·√m14.6 ksi·√in

Hardness, Brinell

250 HB
200 HB

Hardness, Vickers

262 HV
730 HV

Same in both: Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29 · Charpy V-Notch Impact (RT) 6 J4.4 ft·lbf · Hardness, Rockwell B 93 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,300°C2,372 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

47 W/m·K27.2 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
180°C356 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9.5 % IACS
7.8 % IACS

Electrical Resistivity

1.8×10⁻⁷ Ω·m7.09 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 9 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
6 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
6%

Weldability

10 / 100
3 / 100

Formability (cold)

20 / 100
2 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 28 MJ/kg12,038 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleT12A

T12A-CD vs T12A-QT200 — frequently asked

Is T12A-QT200 stronger than T12A-CD?

Yes. T12A-QT200 has a typical yield strength of 1,800 MPa (261 ksi) against 700 MPa (102 ksi) for T12A-CD — about 157% more. Tensile strength is 2,050 MPa (297 ksi) vs 880 MPa (128 ksi).

Which condition does FabDigit quote by default, CD or QT200?

A is the default T12A condition in the FabDigit quote flow (neither CD nor QT200). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, T12A-CD or T12A-QT200?

T12A-CD. Its machinability rates fair (40/100) against not recommended (6/100) for T12A-QT200; for welding the order is T12A-CD first (not recommended, 10/100) then T12A-QT200 (not recommended, 3/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in T12A-CD and T12A-QT200 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.