FabDigitFabDigit

Steel T10 Annealed vs T10-CD

Steel · T10 temper comparison

T10 Annealed and T10-CD are two conditions of the same steel grade, T10: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. T10-CD is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 420 MPa (60.9 ksi) for T10 Annealed, about 48% more; tensile strength follows at 800 MPa (116 ksi) vs 720 MPa (104 ksi). In exchange, T10 Annealed is the more ductile: elongation 18% versus 10% for T10-CD, and T10-CD is harder (235 HB vs 192 HB). T10 Annealed runs hotter in service (300°C vs 200°C continuous).

T10 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

T10-CDChoose it when strength drives the design.

T10 Annealed vs T10-CD: properties

T10 AnnealedT10-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
620 MPa89.9 ksi

Elongation at Break

18%
10%

Reduction in Area

40%
22%

Compressive Strength

450 MPa65.3 ksi
650 MPa94.3 ksi

Shear Strength

440 MPa63.8 ksi
485 MPa70.3 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
360 MPa52.2 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

192 HB
235 HB

Hardness, Rockwell B

92 HRB
99 HRB

Hardness, Vickers

200 HV
247 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.81 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,465°C2,669 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
200°C392 °F

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
44 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
38%

Weldability

15 / 100
10 / 100

Formability (cold)

45 / 100
25 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleT10

T10 Annealed vs T10-CD — frequently asked

Is T10-CD stronger than T10 Annealed?

Yes. T10-CD has a typical yield strength of 620 MPa (89.9 ksi) against 420 MPa (60.9 ksi) for T10 Annealed — about 48% more. Tensile strength is 800 MPa (116 ksi) vs 720 MPa (104 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default T10 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, T10 Annealed or T10-CD?

T10 Annealed. Its weldability rates poor (15/100) against not recommended (10/100) for T10-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in T10 Annealed and T10-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.