FabDigitFabDigit

Steel Super Invar-ANN vs Super Invar CR-H

Steel · Super Invar temper comparison

Super Invar-ANN and Super Invar CR-H are two conditions of the same steel grade, Super Invar: ANN (annealed) versus CR-H (cold Rolled Hard). The chemistry is identical, so every difference below comes from the condition. Super Invar CR-H is the stronger of the two: yield strength 650 MPa (94.3 ksi) against 300 MPa (43.5 ksi) for Super Invar-ANN, about 117% more; tensile strength follows at 750 MPa (109 ksi) vs 500 MPa (72.5 ksi). In exchange, Super Invar-ANN is the more ductile: elongation 35% versus 5% for Super Invar CR-H, and Super Invar CR-H is harder (240 HB vs 150 HB). Super Invar CR-H runs hotter in service (200°C vs 150°C continuous). On the shop floor, Super Invar-ANN welds better (very good vs good).

Super Invar-ANNChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

Super Invar CR-HChoose it when strength drives the design, or when the part sees heat.

Super Invar-ANN vs Super Invar CR-H: properties

Super Invar-ANNSuper Invar CR-H

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

145 GPa21 Msi
148 GPa21.5 Msi

Tensile Strength (Ultimate)

500 MPa72.5 ksi
750 MPa109 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
650 MPa94.3 ksi

Elongation at Break

35%
5%

Reduction in Area

60%
22%

Compressive Strength

310 MPa45 ksi
670 MPa97.2 ksi

Shear Strength

340 MPa49.3 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
350 MPa50.8 ksi

Charpy V-Notch Impact (RT)

130 J95.9 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

150 HB
240 HB

Hardness, Rockwell B

80 HRB
100 HRB

Hardness, Vickers

155 HV
250 HV

Same in both: Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.28 · Fracture Toughness (K_IC) 100 MPa·√m91 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 8.15 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Thermal Conductivity 10.5 W/m·K6.1 BTU/hr·ft·°F · Specific Heat Capacity 515 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 0.5 µm/m·K0.28 µin/in·°F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.2 % IACS
2.1 % IACS

Electrical Resistivity

8×10⁻⁷ Ω·m31.5 µΩ·in
8.2×10⁻⁷ Ω·m32.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 28 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Weldability

70 / 100
60 / 100

Formability (cold)

75 / 100
30 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSuper Invar

Super Invar-ANN vs Super Invar CR-H — frequently asked

Is Super Invar CR-H stronger than Super Invar-ANN?

Yes. Super Invar CR-H has a typical yield strength of 650 MPa (94.3 ksi) against 300 MPa (43.5 ksi) for Super Invar-ANN — about 117% more. Tensile strength is 750 MPa (109 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, ANN or CR-H?

ANN is the default Super Invar condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Super Invar-ANN or Super Invar CR-H?

Super Invar-ANN. Its weldability rates very good (70/100) against good (60/100) for Super Invar CR-H.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Super Invar-ANN and Super Invar CR-H side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.