Steel · SUP6 temper comparison

SUP6-CD and SUP6-N are two conditions of the same steel grade, SUP6: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. SUP6-CD is the stronger of the two: yield strength 700 MPa (102 ksi) against 640 MPa (92.8 ksi) for SUP6-N, about 9% more. In exchange, SUP6-N is the more ductile: elongation 13% versus 10% for SUP6-CD, and SUP6-N is harder (300 HB vs 255 HB). SUP6-N runs hotter in service (300°C vs 250°C continuous). On the shop floor, SUP6-CD machines more easily (50 vs 40 out of 100).

SUP6-CDChoose it when strength drives the design, or when the part is machined in volume.

SUP6-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

SUP6-CD vs SUP6-N: properties

SUP6-CDSUP6-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

880 MPa128 ksi
1,050 MPa152 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
640 MPa92.8 ksi

Elongation at Break

10%
13%

Reduction in Area

35%
32%

Compressive Strength

730 MPa106 ksi
680 MPa98.6 ksi

Shear Strength

530 MPa76.9 ksi
640 MPa92.8 ksi

Fatigue Strength (Endurance Limit)

395 MPa57.3 ksi
470 MPa68.2 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

255 HB
300 HB

Hardness, Rockwell C

24 HRC
31 HRC

Hardness, Vickers

267 HV
315 HV

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
300°C572 °F

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7 % IACS · Electrical Resistivity 2.46×10⁻⁷ Ω·m9.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
45%

Weldability

18 / 100
20 / 100

Formability (cold)

25 / 100
15 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 25 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSUP6

SUP6-CD vs SUP6-N — frequently asked

Is SUP6-CD stronger than SUP6-N?

Yes. SUP6-CD has a typical yield strength of 700 MPa (102 ksi) against 640 MPa (92.8 ksi) for SUP6-N — about 9% more. Tensile strength is 880 MPa (128 ksi) vs 1,050 MPa (152 ksi).

Which condition does FabDigit quote by default, CD or N?

QT44-48 is the default SUP6 condition in the FabDigit quote flow (neither CD nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SUP6-CD or SUP6-N?

SUP6-CD, by a small margin. Both rate fair for machinability — 50/100 against 40/100 for SUP6-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SUP6-CD and SUP6-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.