FabDigitFabDigit

Steel SK4-CD vs SK4 QT56-60

Steel · SK4 temper comparison

SK4-CD and SK4 QT56-60 are two conditions of the same steel grade, SK4: CD (cold drawn) versus QT56-60 (Q&T 56–60 HRC). The chemistry is identical, so every difference below comes from the condition. SK4 QT56-60 is the stronger of the two: yield strength 1,650 MPa (239 ksi) against 620 MPa (89.9 ksi) for SK4-CD, about 166% more; tensile strength follows at 1,950 MPa (283 ksi) vs 800 MPa (116 ksi). In exchange, SK4-CD is the more ductile: elongation 9% versus 1% for SK4 QT56-60, and SK4 QT56-60 is harder (610 HB vs 240 HB). SK4-CD runs hotter in service (200°C vs 180°C continuous) and SK4-CD conducts heat better (47 W/m·K vs 35 W/m·K). On the shop floor, SK4-CD machines more easily (fair vs not recommended).

SK4-CDChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

SK4 QT56-60Choose it when strength drives the design.

SK4-CD vs SK4 QT56-60: properties

SK4-CDSK4 QT56-60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
1,950 MPa283 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
1,650 MPa239 ksi

Elongation at Break

9%
1%

Reduction in Area

30%
2%

Compressive Strength

640 MPa92.8 ksi
2,100 MPa305 ksi

Shear Strength

490 MPa71.1 ksi
1,150 MPa167 ksi

Fatigue Strength (Endurance Limit)

360 MPa52.2 ksi
600 MPa87 ksi

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

240 HB
610 HB

Hardness, Rockwell B

100 HRB
92 HRB

Hardness, Vickers

250 HV
660 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.83 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,465°C2,669 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

47 W/m·K27.2 BTU/hr·ft·°F
35 W/m·K20.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
180°C356 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9.5 % IACS
8.5 % IACS

Electrical Resistivity

1.8×10⁻⁷ Ω·m7.09 µΩ·in
2.05×10⁻⁷ Ω·m8.07 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
8 / 100

Machinability Rating (AISI 1212 = 100 %)

48%
6%

Weldability

12 / 100
3 / 100

Formability (cold)

25 / 100
3 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSK4

SK4-CD vs SK4 QT56-60 — frequently asked

Is SK4 QT56-60 stronger than SK4-CD?

Yes. SK4 QT56-60 has a typical yield strength of 1,650 MPa (239 ksi) against 620 MPa (89.9 ksi) for SK4-CD — about 166% more. Tensile strength is 1,950 MPa (283 ksi) vs 800 MPa (116 ksi).

Which condition does FabDigit quote by default, CD or QT56-60?

A is the default SK4 condition in the FabDigit quote flow (neither CD nor QT56-60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SK4-CD or SK4 QT56-60?

SK4-CD. Its machinability rates fair (48/100) against not recommended (8/100) for SK4 QT56-60; for welding the order is SK4-CD first (not recommended, 12/100) then SK4 QT56-60 (not recommended, 3/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in SK4-CD and SK4 QT56-60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.