FabDigitFabDigit

Steel SCr420-A vs SCr420-CD

Steel · SCr420 temper comparison

SCr420-A and SCr420-CD are two conditions of the same steel grade, SCr420: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. SCr420-CD is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 350 MPa (50.8 ksi) for SCr420-A, about 60% more; tensile strength follows at 680 MPa (98.6 ksi) vs 560 MPa (81.2 ksi). In exchange, SCr420-A is the more ductile: elongation 25% versus 12% for SCr420-CD, and SCr420-CD is harder (200 HB vs 170 HB).

SCr420-AChoose it when the part is bent, formed or impact-loaded.

SCr420-CDChoose it when strength drives the design.

SCr420-A vs SCr420-CD: properties

SCr420-ASCr420-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
680 MPa98.6 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
560 MPa81.2 ksi

Elongation at Break

25%
12%

Reduction in Area

55%
45%

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
300 MPa43.5 ksi

Hardness, Brinell

170 HB
200 HB

Hardness, Rockwell B

87 HRB
94 HRB

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 380 MPa55.1 ksi · Charpy V-Notch Impact (RT) 70 J51.6 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
68%

Formability (cold)

62 / 100
45 / 100

Same in both: Weldability 55 / 100 · Castability 30 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSCr420

SCr420-A vs SCr420-CD — frequently asked

Is SCr420-CD stronger than SCr420-A?

Yes. SCr420-CD has a typical yield strength of 560 MPa (81.2 ksi) against 350 MPa (50.8 ksi) for SCr420-A — about 60% more. Tensile strength is 680 MPa (98.6 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, A or CD?

A is the default SCr420 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SCr420-A or SCr420-CD?

SCr420-CD, by a small margin. Both rate good for machinability — 65/100 against 60/100 for SCr420-A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SCr420-A and SCr420-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.