FabDigitFabDigit

Steel SCM445-A vs SCM445-IH

Steel · SCM445 temper comparison

SCM445-A and SCM445-IH are two conditions of the same steel grade, SCM445: A (solution annealed) versus IH (induction hardened). The chemistry is identical, so every difference below comes from the condition. SCM445-IH is the stronger of the two: yield strength 950 MPa (138 ksi) against 470 MPa (68.2 ksi) for SCM445-A, about 102% more; tensile strength follows at 1,130 MPa (164 ksi) vs 740 MPa (107 ksi). In exchange, SCM445-A is the more ductile: elongation 20% versus 12% for SCM445-IH, and SCM445-IH is harder (600 HB vs 212 HB). SCM445-A runs hotter in service (400°C vs 200°C continuous). On the shop floor, SCM445-A machines more easily (fair vs not recommended) and SCM445-A welds better (poor vs not recommended).

SCM445-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

SCM445-IHChoose it when strength drives the design.

SCM445-A vs SCM445-IH: properties

SCM445-ASCM445-IH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

740 MPa107 ksi
1,130 MPa164 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
950 MPa138 ksi

Elongation at Break

20%
12%

Reduction in Area

50%
45%

Shear Strength

460 MPa66.7 ksi
680 MPa98.6 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
620 MPa89.9 ksi

Fracture Toughness (K_IC)

70 MPa·√m63.7 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

212 HB
600 HB

Hardness, Rockwell C

35 HRC
57 HRC

Hardness, Vickers

345 HV
650 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 960 MPa139 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
200°C392 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
7.5 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
10%

Weldability

30 / 100
10 / 100

Formability (cold)

40 / 100
5 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSCM445

SCM445-A vs SCM445-IH — frequently asked

Is SCM445-IH stronger than SCM445-A?

Yes. SCM445-IH has a typical yield strength of 950 MPa (138 ksi) against 470 MPa (68.2 ksi) for SCM445-A — about 102% more. Tensile strength is 1,130 MPa (164 ksi) vs 740 MPa (107 ksi).

Which condition does FabDigit quote by default, A or IH?

QT is the default SCM445 condition in the FabDigit quote flow (neither A nor IH). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SCM445-A or SCM445-IH?

SCM445-A. Its machinability rates fair (52/100) against not recommended (12/100) for SCM445-IH; for welding the order is SCM445-A first (poor, 30/100) then SCM445-IH (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in SCM445-A and SCM445-IH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.