FabDigitFabDigit

Steel SCM422 Annealed vs SCM422 Cold Drawn

Steel · SCM422 temper comparison

SCM422 Annealed and SCM422 Cold Drawn are two conditions of the same steel grade, SCM422: Annealed versus Cold Drawn. The chemistry is identical, so every difference below comes from the condition. SCM422 Cold Drawn is the stronger of the two: yield strength 600 MPa (87 ksi) against 370 MPa (53.7 ksi) for SCM422 Annealed, about 62% more; tensile strength follows at 730 MPa (106 ksi) vs 580 MPa (84.1 ksi). In exchange, SCM422 Annealed is the more ductile: elongation 25% versus 12% for SCM422 Cold Drawn, and SCM422 Cold Drawn is harder (215 HB vs 170 HB). SCM422 Annealed runs hotter in service (350°C vs 300°C continuous).

SCM422 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

SCM422 Cold DrawnChoose it when strength drives the design.

SCM422 Annealed vs SCM422 Cold Drawn: properties

SCM422 AnnealedSCM422 Cold Drawn

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

580 MPa84.1 ksi
730 MPa106 ksi

Yield Strength (0.2% offset)

370 MPa53.7 ksi
600 MPa87 ksi

Elongation at Break

25%
12%

Reduction in Area

55%
45%

Shear Strength

360 MPa52.2 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
305 MPa44.2 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
28 J20.7 ft·lbf

Hardness, Brinell

170 HB
215 HB

Hardness, Rockwell B

87 HRB
96 HRB

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
64 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
65%

Weldability

40 / 100
38 / 100

Formability (cold)

55 / 100
40 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSCM422

SCM422 Annealed vs SCM422 Cold Drawn — frequently asked

Is SCM422 Cold Drawn stronger than SCM422 Annealed?

Yes. SCM422 Cold Drawn has a typical yield strength of 600 MPa (87 ksi) against 370 MPa (53.7 ksi) for SCM422 Annealed — about 62% more. Tensile strength is 730 MPa (106 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, Annealed or Cold Drawn?

Annealed is the default SCM422 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SCM422 Annealed or SCM422 Cold Drawn?

SCM422 Cold Drawn, by a small margin. Both rate good for machinability — 64/100 against 55/100 for SCM422 Annealed.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SCM422 Annealed and SCM422 Cold Drawn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.