SCM415-CD and SCM415-HR are two conditions of the same steel grade, SCM415: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. SCM415-CD is the stronger of the two: yield strength 600 MPa (87 ksi) against 430 MPa (62.4 ksi) for SCM415-HR, about 40% more; tensile strength follows at 720 MPa (104 ksi) vs 640 MPa (92.8 ksi). In exchange, SCM415-HR is the more ductile: elongation 22% versus 13% for SCM415-CD, and SCM415-CD is harder (215 HB vs 180 HB).

SCM415-CDChoose it when strength drives the design.

SCM415-HRChoose it when the part is bent, formed or impact-loaded.

SCM415-CD vs SCM415-HR: properties

SCM415-CDSCM415-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
640 MPa92.8 ksi

Yield Strength (0.2% offset)

600 MPa87 ksi
430 MPa62.4 ksi

Elongation at Break

13%
22%

Reduction in Area

45%
55%

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
290 MPa42.1 ksi

Hardness, Brinell

215 HB
180 HB

Hardness, Rockwell B

95 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 430 MPa62.4 ksi · Shear Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in · Charpy V-Notch Impact (RT) 55 J40.6 ft·lbf · Hardness, Vickers 190 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,430°C2,606 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 473 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

68%
60%

Formability (cold)

45 / 100
60 / 100

Same in both: Weldability 55 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSCM415

SCM415-CD vs SCM415-HR — frequently asked

Is SCM415-CD stronger than SCM415-HR?

Yes. SCM415-CD has a typical yield strength of 600 MPa (87 ksi) against 430 MPa (62.4 ksi) for SCM415-HR — about 40% more. Tensile strength is 720 MPa (104 ksi) vs 640 MPa (92.8 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default SCM415 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SCM415-CD or SCM415-HR?

SCM415-CD, by a small margin. Both rate good for machinability — 65/100 against 58/100 for SCM415-HR.