FabDigitFabDigit

Steel S355K2 +N vs S355K2 +N-100-150

Steel · S355K2 temper comparison

S355K2 +N and S355K2 +N-100-150 are two conditions of the same steel grade, S355K2: +N (normalized) versus +N-100-150 (+N). The chemistry is identical, so every difference below comes from the condition. S355K2 +N is the stronger of the two: yield strength 400 MPa (58 ksi) against 340 MPa (49.3 ksi) for S355K2 +N-100-150, about 18% more; tensile strength follows at 545 MPa (79 ksi) vs 500 MPa (72.5 ksi). S355K2 +N is the more ductile: elongation 26% versus 23% for S355K2 +N-100-150, and S355K2 +N is harder (160 HB vs 146 HB).

S355K2 +NChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

S355K2 +N vs S355K2 +N-100-150: properties

S355K2 +NS355K2 +N-100-150

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

545 MPa79 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
340 MPa49.3 ksi

Elongation at Break

26%
23%

Reduction in Area

57%
50%

Compressive Strength

400 MPa58 ksi
340 MPa49.3 ksi

Shear Strength

330 MPa47.9 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

245 MPa35.5 ksi
220 MPa31.9 ksi

Fracture Toughness (K_IC)

115 MPa·√m105 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

130 J95.9 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

160 HB
146 HB

Hardness, Rockwell B

84 HRB
78 HRB

Hardness, Vickers

168 HV
153 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
59 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
64%

Weldability

90 / 100
85 / 100

Formability (cold)

68 / 100
58 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS355K2

S355K2 +N vs S355K2 +N-100-150 — frequently asked

Is S355K2 +N stronger than S355K2 +N-100-150?

Yes. S355K2 +N has a typical yield strength of 400 MPa (58 ksi) against 340 MPa (49.3 ksi) for S355K2 +N-100-150 — about 18% more. Tensile strength is 545 MPa (79 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, +N or +N-100-150?

+N is the default S355K2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, S355K2 +N or S355K2 +N-100-150?

S355K2 +N. Its weldability rates excellent (90/100) against excellent (85/100) for S355K2 +N-100-150.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S355K2 +N and S355K2 +N-100-150 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.