FabDigitFabDigit

Steel S25C-CD vs S25C-QT

Steel · S25C temper comparison

S25C-CD and S25C-QT are two conditions of the same steel grade, S25C: CD (cold drawn) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. S25C-CD is the stronger of the two: yield strength 420 MPa (60.9 ksi) against 380 MPa (55.1 ksi) for S25C-QT, about 11% more. In exchange, S25C-QT is the more ductile: elongation 25% versus 15% for S25C-CD, and S25C-QT is harder (170 HB vs 148 HB). On the shop floor, S25C-CD machines more easily (68 vs 58 out of 100).

S25C-CDChoose it when strength drives the design, or when the part is machined in volume.

S25C-QTChoose it when the part is bent, formed or impact-loaded.

S25C-CD vs S25C-QT: properties

S25C-CDS25C-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

510 MPa74 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
380 MPa55.1 ksi

Elongation at Break

15%
25%

Reduction in Area

42%
58%

Shear Strength

325 MPa47.1 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
75 J55.3 ft·lbf

Hardness, Brinell

148 HB
170 HB

Hardness, Rockwell B

80 HRB
87 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 290 MPa42.1 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in · Hardness, Vickers 138 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,515°C2,759 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.7 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
62%

Weldability

82 / 100
85 / 100

Formability (cold)

45 / 100
70 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 75 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS25C

S25C-CD vs S25C-QT — frequently asked

Is S25C-CD stronger than S25C-QT?

Yes. S25C-CD has a typical yield strength of 420 MPa (60.9 ksi) against 380 MPa (55.1 ksi) for S25C-QT — about 11% more. Tensile strength is 510 MPa (74 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, CD or QT?

N is the default S25C condition in the FabDigit quote flow (neither CD nor QT). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S25C-CD or S25C-QT?

S25C-CD, by a small margin. Both rate good for machinability — 68/100 against 58/100 for S25C-QT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S25C-CD and S25C-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.