FabDigitFabDigit

Steel S235J2W +AR vs S235J2W-CR

Steel · S235J2W temper comparison

S235J2W +AR and S235J2W-CR are two conditions of the same steel grade, S235J2W: +AR (hot rolled) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. S235J2W-CR is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 265 MPa (38.4 ksi) for S235J2W +AR, about 43% more; tensile strength follows at 480 MPa (69.6 ksi) vs 420 MPa (60.9 ksi). In exchange, S235J2W +AR is the more ductile: elongation 30% versus 18% for S235J2W-CR, and S235J2W-CR is harder (150 HB vs 125 HB). S235J2W +AR runs hotter in service (350°C vs 300°C continuous).

S235J2W +ARChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

S235J2W-CRChoose it when strength drives the design.

S235J2W +AR vs S235J2W-CR: properties

S235J2W +ARS235J2W-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

265 MPa38.4 ksi
380 MPa55.1 ksi

Elongation at Break

30%
18%

Reduction in Area

55%
40%

Compressive Strength

250 MPa36.3 ksi
380 MPa55.1 ksi

Shear Strength

270 MPa39.2 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
210 MPa30.5 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
80 MPa·√m72.8 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

125 HB
150 HB

Hardness, Rockwell B

70 HRB
80 HRB

Hardness, Vickers

132 HV
158 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,470°C2,678 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.6 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 30 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
66 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
64%

Weldability

88 / 100
85 / 100

Formability (cold)

80 / 100
60 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS235J2W

S235J2W +AR vs S235J2W-CR — frequently asked

Is S235J2W-CR stronger than S235J2W +AR?

Yes. S235J2W-CR has a typical yield strength of 380 MPa (55.1 ksi) against 265 MPa (38.4 ksi) for S235J2W +AR — about 43% more. Tensile strength is 480 MPa (69.6 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, +AR or CR?

+AR is the default S235J2W condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose S235J2W +AR over S235J2W-CR?

Pick S235J2W +AR when the part is bent, formed or impact-loaded, or when the part sees heat. Pick S235J2W-CR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S235J2W +AR and S235J2W-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.