FabDigitFabDigit

Steel S20CK-A vs S20CK-WQT

Steel · S20CK temper comparison

S20CK-A and S20CK-WQT are two conditions of the same steel grade, S20CK: A (solution annealed) versus WQT (water quenched and tempered). The chemistry is identical, so every difference below comes from the condition. S20CK-WQT is the stronger of the two: yield strength 390 MPa (56.6 ksi) against 240 MPa (34.8 ksi) for S20CK-A, about 63% more; tensile strength follows at 560 MPa (81.2 ksi) vs 400 MPa (58 ksi). In exchange, S20CK-A is the more ductile: elongation 34% versus 22% for S20CK-WQT, and S20CK-WQT is harder (170 HB vs 115 HB).

S20CK-AChoose it when the part is bent, formed or impact-loaded.

S20CK-WQTChoose it when strength drives the design.

S20CK-A vs S20CK-WQT: properties

S20CK-AS20CK-WQT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
390 MPa56.6 ksi

Elongation at Break

34%
22%

Reduction in Area

64%
55%

Shear Strength

280 MPa40.6 ksi
370 MPa53.7 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

95 J70.1 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

115 HB
170 HB

Hardness, Rockwell B

64 HRB
87 HRB

Hardness, Vickers

121 HV
178 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,525°C2,777 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
49 W/m·K28.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 477 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10.2 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.69×10⁻⁷ Ω·m6.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
54 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
60%

Weldability

92 / 100
85 / 100

Formability (cold)

88 / 100
55 / 100

Same in both: Brazeability / Solderability 80 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS20CK

S20CK-A vs S20CK-WQT — frequently asked

Is S20CK-WQT stronger than S20CK-A?

Yes. S20CK-WQT has a typical yield strength of 390 MPa (56.6 ksi) against 240 MPa (34.8 ksi) for S20CK-A — about 63% more. Tensile strength is 560 MPa (81.2 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, A or WQT?

HR is the default S20CK condition in the FabDigit quote flow (neither A nor WQT). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, S20CK-A or S20CK-WQT?

S20CK-A. Its weldability rates excellent (92/100) against excellent (85/100) for S20CK-WQT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S20CK-A and S20CK-WQT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.