FabDigitFabDigit

Steel S20C-A vs S20C-HR

Steel · S20C temper comparison

S20C-A and S20C-HR are two conditions of the same steel grade, S20C: A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. S20C-HR is the stronger of the two: yield strength 260 MPa (37.7 ksi) against 240 MPa (34.8 ksi) for S20C-A, about 8% more; tensile strength follows at 420 MPa (60.9 ksi) vs 395 MPa (57.3 ksi). In exchange, S20C-A is the more ductile: elongation 34% versus 30% for S20C-HR, and S20C-HR is harder (121 HB vs 111 HB).

S20C-AChoose it when the part is bent, formed or impact-loaded.

S20C-HRChoose it when strength drives the design.

S20C-A vs S20C-HR: properties

S20C-AS20C-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

395 MPa57.3 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
260 MPa37.7 ksi

Elongation at Break

34%
30%

Reduction in Area

64%
60%

Shear Strength

330 MPa47.9 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

111 HB
121 HB

Hardness, Rockwell B

62 HRB
68 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in · Hardness, Vickers 150 HV

Physical

Density and transition temperatures.

Same in both: Density 7.86 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,490°C2,714 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

46 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

52%
55%

Formability (cold)

88 / 100
78 / 100

Same in both: Weldability 95 / 100 · Castability 40 / 100 · Brazeability / Solderability 80 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS20C

S20C-A vs S20C-HR — frequently asked

Is S20C-HR stronger than S20C-A?

Yes. S20C-HR has a typical yield strength of 260 MPa (37.7 ksi) against 240 MPa (34.8 ksi) for S20C-A — about 8% more. Tensile strength is 420 MPa (60.9 ksi) vs 395 MPa (57.3 ksi).

Which condition does FabDigit quote by default, A or HR?

CD is the default S20C condition in the FabDigit quote flow (neither A nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose S20C-A over S20C-HR?

Pick S20C-A when the part is bent, formed or impact-loaded. Pick S20C-HR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S20C-A and S20C-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.