FabDigitFabDigit

Steel Q355C-CD vs Q355C-HR

Steel · Q355C temper comparison

Q355C-CD and Q355C-HR are two conditions of the same steel grade, Q355C: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. Q355C-CD is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 380 MPa (55.1 ksi) for Q355C-HR, about 37% more; tensile strength follows at 620 MPa (89.9 ksi) vs 520 MPa (75.4 ksi). In exchange, Q355C-HR is the more ductile: elongation 26% versus 12% for Q355C-CD, and Q355C-CD is harder (185 HB vs 150 HB).

Q355C-CDChoose it when strength drives the design.

Q355C-HRChoose it when the part is bent, formed or impact-loaded.

Q355C-CD vs Q355C-HR: properties

Q355C-CDQ355C-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
380 MPa55.1 ksi

Elongation at Break

12%
26%

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

185 HB
150 HB

Hardness, Rockwell B

90 HRB
80 HRB

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3 · Reduction in Area 50% · Compressive Strength 380 MPa55.1 ksi · Shear Strength 340 MPa49.3 ksi · Fracture Toughness (K_IC) 100 MPa·√m91 ksi·√in · Hardness, Vickers 158 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,500°C2,732 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature 0°C32 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.2 % IACS · Electrical Resistivity 2.1×10⁻⁷ Ω·m8.27 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

72%
68%

Weldability

80 / 100
85 / 100

Formability (cold)

45 / 100
70 / 100

Same in both: Machinability 60 / 100 · Brazeability / Solderability 55 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 24 MJ/kg10,318 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ355C

Q355C-CD vs Q355C-HR — frequently asked

Is Q355C-CD stronger than Q355C-HR?

Yes. Q355C-CD has a typical yield strength of 520 MPa (75.4 ksi) against 380 MPa (55.1 ksi) for Q355C-HR — about 37% more. Tensile strength is 620 MPa (89.9 ksi) vs 520 MPa (75.4 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default Q355C condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Q355C-CD or Q355C-HR?

Q355C-HR. Its weldability rates excellent (85/100) against very good (80/100) for Q355C-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q355C-CD and Q355C-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.