Q275-ANN and Q275-N are two conditions of the same steel grade, Q275: ANN (annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. Q275-N is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 255 MPa (37 ksi) for Q275-ANN, about 18% more; tensile strength follows at 490 MPa (71.1 ksi) vs 430 MPa (62.4 ksi). Q275-N is harder — 148 HB against 128 HB for Q275-ANN — which matters for wear surfaces and threads.

Q275-NChoose it when strength drives the design, or when surface hardness matters.

Q275-ANN vs Q275-N: properties

Q275-ANNQ275-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

430 MPa62.4 ksi
490 MPa71.1 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
300 MPa43.5 ksi

Elongation at Break

28%
26%

Reduction in Area

53%
49%

Compressive Strength

255 MPa37 ksi
300 MPa43.5 ksi

Shear Strength

275 MPa39.9 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
220 MPa31.9 ksi

Fracture Toughness (K_IC)

78 MPa·√m71 ksi·√in
72 MPa·√m65.5 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

128 HB
148 HB

Hardness, Rockwell B

71 HRB
80 HRB

Hardness, Vickers

134 HV
156 HV

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

49 W/m·K28.3 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

63 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

68%
65%

Weldability

72 / 100
70 / 100

Formability (cold)

65 / 100
58 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ275

Q275-ANN vs Q275-N — frequently asked

Is Q275-N stronger than Q275-ANN?

Yes. Q275-N has a typical yield strength of 300 MPa (43.5 ksi) against 255 MPa (37 ksi) for Q275-ANN — about 18% more. Tensile strength is 490 MPa (71.1 ksi) vs 430 MPa (62.4 ksi).

Which condition does FabDigit quote by default, ANN or N?

HR is the default Q275 condition in the FabDigit quote flow (neither ANN nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Q275-ANN over Q275-N?

Pick Q275-N when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q275-ANN and Q275-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.