Q235A-CD and Q235A-HR are two conditions of the same steel grade, Q235A: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. Q235A-CD is the stronger of the two: yield strength 400 MPa (58 ksi) against 255 MPa (37 ksi) for Q235A-HR, about 57% more; tensile strength follows at 510 MPa (74 ksi) vs 420 MPa (60.9 ksi). In exchange, Q235A-HR is the more ductile: elongation 28% versus 12% for Q235A-CD, and Q235A-CD is harder (163 HB vs 131 HB).

Q235A-CDChoose it when strength drives the design.

Q235A-HRChoose it when the part is bent, formed or impact-loaded.

Q235A-CD vs Q235A-HR: properties

Q235A-CDQ235A-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

510 MPa74 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
255 MPa37 ksi

Elongation at Break

12%
28%

Reduction in Area

45%
55%

Fatigue Strength (Endurance Limit)

220 MPa31.9 ksi
185 MPa26.8 ksi

Hardness, Brinell

163 HB
131 HB

Hardness, Rockwell B

84 HRB
72 HRB

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 255 MPa37 ksi · Shear Strength 265 MPa38.4 ksi · Fracture Toughness (K_IC) 60 MPa·√m54.6 ksi·√in · Charpy V-Notch Impact (RT) 40 J29.5 ft·lbf · Hardness, Vickers 138 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 472 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature 0°C32 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
68%

Weldability

90 / 100
92 / 100

Formability (cold)

55 / 100
82 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 75 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 35 L/kg4.2 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ235A

Q235A-CD vs Q235A-HR — frequently asked

Is Q235A-CD stronger than Q235A-HR?

Yes. Q235A-CD has a typical yield strength of 400 MPa (58 ksi) against 255 MPa (37 ksi) for Q235A-HR — about 57% more. Tensile strength is 510 MPa (74 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default Q235A condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Q235A-CD or Q235A-HR?

Q235A-CD. Its machinability rates very good (70/100) against good (65/100) for Q235A-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q235A-CD and Q235A-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.