FabDigitFabDigit

Steel P690QH-QT vs P690QH QT-50-100

Steel · P690QH temper comparison

P690QH-QT and P690QH QT-50-100 are two conditions of the same steel grade, P690QH: QT (quenched and tempered) versus QT-50-100 (QT). The chemistry is identical, so every difference below comes from the condition. P690QH-QT is the stronger of the two: yield strength 740 MPa (107 ksi) against 700 MPa (102 ksi) for P690QH QT-50-100, about 6% more. P690QH-QT is harder — 26 HRC against 24 HRC for P690QH QT-50-100 — which matters for wear surfaces and threads.

P690QH-QTChoose it when strength drives the design, or when surface hardness matters.

P690QH-QT vs P690QH QT-50-100: properties

P690QH-QTP690QH QT-50-100

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

830 MPa120 ksi
820 MPa119 ksi

Yield Strength (0.2% offset)

740 MPa107 ksi
700 MPa102 ksi

Reduction in Area

55%
53%

Compressive Strength

740 MPa107 ksi
700 MPa102 ksi

Shear Strength

500 MPa72.5 ksi
490 MPa71.1 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
360 MPa52.2 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
125 MPa·√m114 ksi·√in

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

260 HB
250 HB

Hardness, Rockwell C

26 HRC
24 HRC

Hardness, Vickers

273 HV
262 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 166 GPa24.1 Msi · Poisson's Ratio 0.3 · Elongation at Break 17%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 36 W/m·K20.8 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature 0°C32 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6.6 % IACS · Electrical Resistivity 2.6×10⁻⁷ Ω·m10.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
47%

Weldability

65 / 100
63 / 100

Formability (cold)

40 / 100
38 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP690QH

P690QH-QT vs P690QH QT-50-100 — frequently asked

Is P690QH-QT stronger than P690QH QT-50-100?

Yes. P690QH-QT has a typical yield strength of 740 MPa (107 ksi) against 700 MPa (102 ksi) for P690QH QT-50-100 — about 6% more. Tensile strength is 830 MPa (120 ksi) vs 820 MPa (119 ksi).

Which condition does FabDigit quote by default, QT or QT-50-100?

QT is the default P690QH condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose P690QH-QT over P690QH QT-50-100?

Pick P690QH-QT when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in P690QH-QT and P690QH QT-50-100 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.