P500QL1 QT-100-150 and P500QL1 QT-50-100 are two conditions of the same steel grade, P500QL1: QT-100-150 (Q&T) versus QT-50-100 (Q&T). The chemistry is identical, so every difference below comes from the condition. P500QL1 QT-50-100 is the stronger of the two: yield strength 530 MPa (76.9 ksi) against 480 MPa (69.6 ksi) for P500QL1 QT-100-150, about 10% more. P500QL1 QT-50-100 is harder — 15 HRC against 13 HRC for P500QL1 QT-100-150 — which matters for wear surfaces and threads.

P500QL1 QT-50-100Choose it when strength drives the design, or when surface hardness matters.

P500QL1 QT-100-150 vs P500QL1 QT-50-100: properties

P500QL1 QT-100-150P500QL1 QT-50-100

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

610 MPa88.5 ksi
640 MPa92.8 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
530 MPa76.9 ksi

Elongation at Break

19%
20%

Reduction in Area

55%
58%

Compressive Strength

480 MPa69.6 ksi
530 MPa76.9 ksi

Shear Strength

370 MPa53.7 ksi
385 MPa55.8 ksi

Fatigue Strength (Endurance Limit)

275 MPa39.9 ksi
290 MPa42.1 ksi

Fracture Toughness (K_IC)

140 MPa·√m127 ksi·√in
145 MPa·√m132 ksi·√in

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
130 J95.9 ft·lbf

Hardness, Brinell

195 HB
200 HB

Hardness, Rockwell B

92 HRB
93 HRB

Hardness, Rockwell C

13 HRC
15 HRC

Hardness, Vickers

205 HV
210 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 40 W/m·K23.1 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 14 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

47 / 100
46 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
57%

Weldability

56 / 100
58 / 100

Formability (cold)

40 / 100
42 / 100

Same in both: Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP500QL1

P500QL1 QT-100-150 vs P500QL1 QT-50-100 — frequently asked

Is P500QL1 QT-50-100 stronger than P500QL1 QT-100-150?

Yes. P500QL1 QT-50-100 has a typical yield strength of 530 MPa (76.9 ksi) against 480 MPa (69.6 ksi) for P500QL1 QT-100-150 — about 10% more. Tensile strength is 640 MPa (92.8 ksi) vs 610 MPa (88.5 ksi).

Which condition does FabDigit quote by default, QT-100-150 or QT-50-100?

QT is the default P500QL1 condition in the FabDigit quote flow (neither QT-100-150 nor QT-50-100). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose P500QL1 QT-100-150 over P500QL1 QT-50-100?

Pick P500QL1 QT-50-100 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in P500QL1 QT-100-150 and P500QL1 QT-50-100 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.