FabDigitFabDigit

Steel P500Q-QT vs P500Q-SR

Steel · P500Q temper comparison

P500Q-QT and P500Q-SR are two conditions of the same steel grade, P500Q: QT (quenched and tempered) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. P500Q-QT is the stronger of the two: yield strength 545 MPa (79 ksi) against 510 MPa (74 ksi) for P500Q-SR, about 7% more. P500Q-QT is harder — 215 HB against 200 HB for P500Q-SR — which matters for wear surfaces and threads.

P500Q-QTChoose it when strength drives the design, or when surface hardness matters.

P500Q-QT vs P500Q-SR: properties

P500Q-QTP500Q-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

660 MPa95.7 ksi
630 MPa91.4 ksi

Yield Strength (0.2% offset)

545 MPa79 ksi
510 MPa74 ksi

Elongation at Break

20%
21%

Reduction in Area

58%
60%

Compressive Strength

545 MPa79 ksi
510 MPa74 ksi

Shear Strength

400 MPa58 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
285 MPa41.3 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
115 MPa·√m105 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
95 J70.1 ft·lbf

Hardness, Brinell

215 HB
200 HB

Hardness, Rockwell B

95 HRB
93 HRB

Hardness, Rockwell C

19 HRC
15 HRC

Hardness, Vickers

225 HV
210 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 38 W/m·K22 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature 0°C32 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.2 % IACS · Electrical Resistivity 2.4×10⁻⁷ Ω·m9.45 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
58%

Weldability

70 / 100
72 / 100

Formability (cold)

45 / 100
48 / 100

Same in both: Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP500Q

P500Q-QT vs P500Q-SR — frequently asked

Is P500Q-QT stronger than P500Q-SR?

Yes. P500Q-QT has a typical yield strength of 545 MPa (79 ksi) against 510 MPa (74 ksi) for P500Q-SR — about 7% more. Tensile strength is 660 MPa (95.7 ksi) vs 630 MPa (91.4 ksi).

Which condition does FabDigit quote by default, QT or SR?

QT is the default P500Q condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose P500Q-QT over P500Q-SR?

Pick P500Q-QT when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in P500Q-QT and P500Q-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.