FabDigitFabDigit

Steel P460Q-QT vs P460Q QT-100-150

Steel · P460Q temper comparison

P460Q-QT and P460Q QT-100-150 are two conditions of the same steel grade, P460Q: QT (quenched and tempered) versus QT-100-150 (QT). The chemistry is identical, so every difference below comes from the condition. P460Q-QT is the stronger of the two: yield strength 510 MPa (74 ksi) against 450 MPa (65.3 ksi) for P460Q QT-100-150, about 13% more; tensile strength follows at 620 MPa (89.9 ksi) vs 580 MPa (84.1 ksi). P460Q-QT is harder — 200 HB against 185 HB for P460Q QT-100-150 — which matters for wear surfaces and threads.

P460Q-QTChoose it when strength drives the design, or when surface hardness matters.

P460Q-QT vs P460Q QT-100-150: properties

P460Q-QTP460Q QT-100-150

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

510 MPa74 ksi
450 MPa65.3 ksi

Elongation at Break

21%
20%

Reduction in Area

55%
52%

Compressive Strength

510 MPa74 ksi
450 MPa65.3 ksi

Shear Strength

390 MPa56.6 ksi
360 MPa52.2 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
260 MPa37.7 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

130 J95.9 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

200 HB
185 HB

Hardness, Rockwell C

17 HRC
12 HRC

Hardness, Vickers

210 HV
195 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,450°C2,642 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 465 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
53 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
58%

Weldability

72 / 100
68 / 100

Formability (cold)

45 / 100
42 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP460Q

P460Q-QT vs P460Q QT-100-150 — frequently asked

Is P460Q-QT stronger than P460Q QT-100-150?

Yes. P460Q-QT has a typical yield strength of 510 MPa (74 ksi) against 450 MPa (65.3 ksi) for P460Q QT-100-150 — about 13% more. Tensile strength is 620 MPa (89.9 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, QT or QT-100-150?

QT is the default P460Q condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose P460Q-QT over P460Q QT-100-150?

Pick P460Q-QT when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in P460Q-QT and P460Q QT-100-150 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.